Indoor Air Quality Archives - Thomson Environmental Systems https://thomsongroup.com.au/industries/indoor-air-quality/ Mon, 01 Dec 2025 02:57:48 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Indoor Air Quality Archives - Thomson Environmental Systems https://thomsongroup.com.au/industries/indoor-air-quality/ 32 32 MesaLabs Flexcal Series https://thomsongroup.com.au/product/mesalabs-flexcal-series/ Thu, 12 Jun 2025 01:17:57 +0000 https://thomsongroup.com.au/?post_type=product&p=21047 Highly Accurate Portable Gas Flow Calibrator Mesa Labs’ newest standardized and volumetric primary flow standard offers easy-to-navigate calibrations with unparalleled flow ranges, accuracy and portability. The FlexCal features: USB connectivity Flow ranges from 5 ccm to 50 LPM Quick start operation Graphical LCD display User-selectable flow units and time interval CE/RoHS Compliant The FlexCal offers […]

The post MesaLabs Flexcal Series appeared first on Thomson Environmental Systems.

]]>
Highly Accurate Portable Gas Flow Calibrator

Mesa Labs’ newest standardized and volumetric primary flow standard offers easy-to-navigate calibrations with unparalleled flow ranges, accuracy and portability. The FlexCal features:

  • USB connectivity
  • Flow ranges from 5 ccm to 50 LPM
  • Quick start operation
  • Graphical LCD display
  • User-selectable flow units and time interval
  • CE/RoHS Compliant

The FlexCal offers flow ranges up to 50 LPM with a standardized accuracy of 0.5%, but is small, easy to carry and ready for even the most demanding of applications. When you use Mesa Labs’ FlexCal, you are guaranteed high accuracy with high confidence without the use of soap bubbles, timers, or heavy provers.

Download Data Sheet

Technical Specifications

  FlexCal-H FlexCal-M FlexCal-L
Flow Ranges 0.5 – 50 LPM 50 ccm – 5 LPM 5 – 500 ccm
Accuracy 0.5% of reading
User selectable
measurement units
Volumetric mL/min, L/min, cc/min, cf/min
Standardised smL/min, sL/min, scc/min, scf/min
Temperature oC    oF
Pressure mmHg, PSI, kPa
Temperature and Pressure sensor Yes, in flow stream
Dimensions (HxWxD) 6.7 x 6.25 x 2.9 in / 170 x 159 x 73.5 mm
Weight 3 lb / 1.36 kg

The post MesaLabs Flexcal Series appeared first on Thomson Environmental Systems.

]]>
Bacterial Filtration Efficiency (BFE) Testing System https://thomsongroup.com.au/product/bacterial-filtration-efficiency-bfe-testing-system/ Tue, 15 Oct 2024 04:50:44 +0000 https://thomsongroup.com.au/?post_type=product&p=20573 The Bacterial Filter Efficiency (BFE) Test Rig developed by CH Technologies allows for the testing of medical face mask materials and filters according to ASTM 2101, IS 16289, and EN 14683 with Staphylococcus Aureus. This turn-key system provides a quantitative method for determining the filter efficiency of mask materials with a maximum filtration efficiency of […]

The post Bacterial Filtration Efficiency (BFE) Testing System appeared first on Thomson Environmental Systems.

]]>
The Bacterial Filter Efficiency (BFE) Test Rig developed by CH Technologies allows for the testing of medical face mask materials and filters according to ASTM 2101, IS 16289, and EN 14683 with Staphylococcus Aureus. This turn-key system provides a quantitative method for determining the filter efficiency of mask materials with a maximum filtration efficiency of 99.9%.

Available in both Glass or Stainless Steel Column configurations. The BLAM is the aerosol generator of choice for this test rig which allows for a tunable size distribution to provide a bio-aerosol with an average diameter of 3.0 microns.

For further information regarding this system, please see the following publication.
Parthasarathi Kalaiselvan, Shyam Sunder Tummanapalli, Ajay Kumar Vijay, Prateek Bahl, Chandini Raina MacIntyre & Mark D P Willcox. The ability of face masks to reduce the transmission of microbes. Accepted 13 Aug 2021, published online 30 Sep 2021. https://doi.org/10.1080/08164622.2021.1971050

Product Benefits

  • For testing according to ASTM 2101 with Staphylococcus Aureus
  • Complete test rig with everything you need to get started immediately
  • Available in Glass or SS configurations
  • Provides quick and reliable results
  • Short set up time

Components

  • Glass or SS Aerosol Column with Built-In Mask/ Media Holder
  • 4 Jet Standard Flow BLAM Atomizer
  • Syringe Pump
  • 6 Stage Viable Cascade Impactor
  • Control Unit (Includes Calibrated Rotameters, Pressure Regulator, Pressure Gauge, Flow Switches, Filters and Tubing)
  • EPA Filters and Dryer
  • Custom Ring Stand with Lab Jack Support
  • Rotary Vein Vacuum Pump

Operation

  • The liquid test article (Bacterial Solution) is loaded into the syringe pump.
  • The test article is then injected into the BLAM atomizer at a controlled rate.
  • Agar Plates/Pitri dishes are mounted on different stages of the viable impactor.
  • The test specimen(filter media) is clamped into the system for subsequent exposure.
  • The BLAM generates a bio-aerosol from the test article solution inside the Glass or Steel Column.
  • The agar plates are taken out for further analysis.

 

Data Sheet

The post Bacterial Filtration Efficiency (BFE) Testing System appeared first on Thomson Environmental Systems.

]]>
Clarity Ozone Module https://thomsongroup.com.au/product/clarity-ozone-module/ Tue, 19 Mar 2024 02:25:12 +0000 https://thomsongroup.com.au/?post_type=product&p=20090 The Clarity Ozone Module is based on best-in-class technology from 2B Technologies, and provides accurate measurements of ozone in air over a wide dynamic range extending from a few parts-per-billion by volume (ppb) to an upper limit of 100 parts-per-million (ppm) based on the well-established technique of absorption of ultraviolet light at 254 nm. The […]

The post Clarity Ozone Module appeared first on Thomson Environmental Systems.

]]>
The Clarity Ozone Module is based on best-in-class technology from 2B Technologies, and provides accurate measurements of ozone in air over a wide dynamic range extending from a few parts-per-billion by volume (ppb) to an upper limit of 100 parts-per-million (ppm) based on the well-established technique of absorption of ultraviolet light at 254 nm.

The Ozone Module integrates seamlessly into Clarity networks with an ozone monitoring technology has been approved by the U.S. Environmental Protection Agency as a modification of Federal Equivalent Method (FEM): EQOA-0914-218. The Ozone Module is well suited for use by states and other monitoring agencies under 40 CFR Part 58, Ambient Air Quality Surveillance, for monitoring for compliance with the Clean Air Act.

Download Specifications

The post Clarity Ozone Module appeared first on Thomson Environmental Systems.

]]>
Oxygen Sensors https://thomsongroup.com.au/product/oxygen-sensors/ Thu, 04 May 2023 04:33:23 +0000 https://thomsongroup.com.au/?post_type=product&p=19962 Sensors for Oxygen Analyzers   ​ ​Class ​Part Numbe​r ​Application ​Warranty ​ A-2C​​ ​C06689-A2C ​​Used for trace Oxygen (O2) measurements in Carbon Dioxide (CO2) containing backgrounds (0.1-100% CO2). CO2 must be present ​6 months ​ ​A-2CXL​ ​B74033-A2CXL ​Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm ​6 months ​ […]

The post Oxygen Sensors appeared first on Thomson Environmental Systems.

]]>

Sensors for Oxygen Analyzers

  ​ ​Class ​Part Numbe​r Application ​Warranty A-2C​​ ​C06689-A2C ​​Used for trace Oxygen (O2) measurements in Carbon Dioxide (CO2) containing backgrounds (0.1-100% CO2). CO2 must be present ​6 months ​ ​A-2CXL​ ​B74033-A2CXL ​Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm ​6 months ​ A-5​​ ​C06689-A5 ​Intermittent or continuous monitoring of percent Oxygen (O2) in gas mixtures containing 0-100% Carbon Dioxide (CO2). 90% response time is 45 seconds 6 months ​ ​B-1​​ ​C06689-B1 ​General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds) ​6 months ​B-1C ​C06689-B1C ​General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds)​ ​6 months

  ​B-2C​​ ​​C06689-B2C ​​General purpose trace Oxygen (O2) analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. ​6 months ​ ​B-2CXL​ ​C06689-B2CXL ​Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. ​​6 months ​ ​B-3 ​C06689-B3 ​Percent Oxygen (O2) analysis, best compromise between long life and fast response ​12 months ​ E​-2​​ ​C57283-E2 ​Long life cell for use is the model 3290 (for use in unattended air liquefaction nitrogen skids) ​​24 months​ ​ ​InstaTrace​ ​B71875 ​​Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes.​ ​6 months ​ ​InstaTrace-CO2
​B73016 ​​Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes.​ ​6 months Insta​Trace-XL​
​ ​B73592 ​Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes.​ ​​​6 months ​L-2C​ ​C06689-L2C ​Used for general purpose trace oxygen analysis in the 3000T analyzer series 12​ months


 
Auto​motiv​​​e Sensors
​Class Part Number Applications Warranty
​ ​ R-17A​​ ​C43690-R17A ​The “R” series of sensors are used by most automotive emission equipment manufacturers worldwide. 12 months
​R-21A​​ ​C43981-R21A ​The “R” series of sensors are used by most automotive emission equipment manufacturers worldwide. 12 months
R-22A​​ ​​C44611-R22A ​The “R” series of sensors are used by most automotive emission equipment manufacturers worldwide.​ 12 months

Back to Top

 

 

Diving Sensors
​Class Part Number Applications Warranty
R-1​7S​​ ​C72144-R17S ​Cylinder blend checking for sports diving with minim phone jack connector 12 months
​R-22S​ ​C72148-R22S ​Cylinder blend checking for sports diving with Molex 3-pin connector ​12 months
​R-33S​ ​C74069-R33S ​High output for driving LCD directly in small, handheld instruments ​12 months
​R-33S-1​ ​C74069-R33S1 ​High output for driving LCD directly in small, handheld instruments ​12 months

Back to Top

Oxygen Sensors range brochure

The post Oxygen Sensors appeared first on Thomson Environmental Systems.

]]>
TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) https://thomsongroup.com.au/product/tes-small-form-air-quality-monitoring-systems-aqms/ Fri, 03 Jul 2020 04:28:21 +0000 https://thomsongroup.com.au/?post_type=product&p=17869 Your Solution for Ambient Air Quality Monitoring Ideal for monitoring air quality outside or in workshops, TES Small Form AQMS measures key parameters: Air pollutant concentrations: PM1, PM2.5, PM4, PM10, TSP, O3, NO, NO2, O3, CO, SO2, H2S, NH3, HCHO, Cl2, HCl, VOC, CH4, CO2 – other gases available on request Meteorological parameters: temperature, pressure and relative […]

The post TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) appeared first on Thomson Environmental Systems.

]]>
Your Solution for Ambient Air Quality Monitoring

Ideal for monitoring air quality outside or in workshops, TES Small Form AQMS measures key parameters:

Air pollutant concentrations: PM1, PM2.5, PM4, PM10, TSP, O3, NO, NO2, O3, CO, SO2, H2S, NH3, HCHO, Cl2, HCl, VOC, CH4, CO2 – other gases available on request

Meteorological parameters: temperature, pressure and relative humidity

Other parameters: noise, vibration and odour

Location: GPS

The device captures data in real-time and transfers them wirelessly to a advanced web platform, for data analysis and data management, remote control of the equipment and data integration into websites, software and smart city platforms.

Small form stations are light, compact and easy to install within just a few minutes. Once the stations are connected to the Internet through several communication links on-demand (Wi-Fi, 3/4G, LoRa, Zigbee…), the hyper-localised information is automatically transferred to a secure web platform that is accessible 24 hours a day.

Customize your own Small Form AQMS that meets your needs:

Options:

  • Integrate sensors that you need
  • Choose your communication link
  • Add a back-up battery 

Accessories:

  • Solar panel and batteries
  • Heating resistance
  • Mounting plate

For a wide range of applications:

Smart cities, industrial sites, mining sites, sewage treatment plants, mines, soil remediation, refineries, workshops, warehouses, worksites, road networks, race tracks, ski, and sea resorts.

The post TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) appeared first on Thomson Environmental Systems.

]]>
GASMET GT5000 Terra FTIR Gas Analyzer https://thomsongroup.com.au/product/gasmet-gt5000-terra-multigas-analyser/ Wed, 11 Dec 2019 23:01:17 +0000 https://thomsongroup.com.au/?post_type=product&p=17822 The Gasmet GT5000 Terra FTIR Gas Analyzer is a portable FTIR multi-Component gas analyzer ideally suited to numerous applications involving indoor and outdoor air monitoring of non-condensing gases, including Green House Gases (GHG). Typical applications are dynamic situations in the field including: Toxic gas monitoring for emergency service personnel Monitoring shipping containers Soil monitoring. 50 […]

The post GASMET GT5000 Terra FTIR Gas Analyzer appeared first on Thomson Environmental Systems.

]]>
The Gasmet GT5000 Terra FTIR Gas Analyzer is a portable FTIR multi-Component gas analyzer ideally suited to numerous applications involving indoor and outdoor air monitoring of non-condensing gases, including Green House Gases (GHG).

Typical applications are dynamic situations in the field including:

  • Toxic gas monitoring for emergency service personnel
  • Monitoring shipping containers
  • Soil monitoring.

50 gases can be analyzed at the same time using the supplied touch-screen tablet.

The GT5000 is ideal for on-site measurements of both organic and inorganic compounds at low concentrations in ambient air. Typical applications are industrial hygiene, emergency response and security/border protection.

  • Accounts for interferences and can identify unknown compounds
  • Can measure 50 gases simultaneously
  • Raw data is saved for post analysis
  • Library of >200 gases available for measurement and library of 5000+ for identification of unknown gases
  • Sub PPM levels possible without pre-concentration ensuring quick response time
  • Zero Calibration on clean air or Nitrogen is the only calibration required.
  • Weighs just 9.4 kgs
  • Internal battery and sample pump inside the backpack unit, makes it easy to carry on in the field.

Gasmet GT5000 can be equipped with customized equipment packages to match the user’s specific needs.

It comes with updated Calcmet software for intuitive measurement in the field – the touch screen tablet is a robust device which can be easily used with and without gloves, or by using a pen.

The new GT5000 Terra is capable of measuring over 300 gases and up to 50 gases simultaneously. It has all the advantages of FTIR technology. It is quick to setup, easy to operate and low total cost-of-ownership.

 

View Video

Download Specifications

The post GASMET GT5000 Terra FTIR Gas Analyzer appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) https://thomsongroup.com.au/product/teledyne-api-model-430-portable-fem-ozone-analyzer/ Mon, 19 Nov 2018 02:31:41 +0000 https://thomsongroup.com.au/?post_type=product&p=17319 The Model 430 03 monitor uses the proven UV Absorption principle, producing accurate and stable O3 measurements. The small footprint and quiet operation make it extremely useful for ambient air and indoor air quality, surveying, and industrial hygiene applications. Model 430 carries US EPA Federal Equivalent Method EQOA-1015-229 certification. The Model 430 Compact O3 Analyzer […]

The post TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model 430 03 monitor uses the proven UV Absorption principle, producing accurate and stable O3 measurements.
The small footprint and quiet operation make it extremely useful for ambient air and indoor air quality, surveying, and industrial hygiene applications.

Model 430 carries US EPA Federal Equivalent Method EQOA-1015-229 certification.

The Model 430 Compact O3 Analyzer uses the proven UV Absorption principle, to produce accurate and stable O3 measurements. The robust design and low power consumption makes it ideal for portable monitoring applications such as rural and remote monitoring, saturation studies, and atmospheric research.

The small footprint and quiet operation make it extremely useful for indoor air quality, surveying, and industrial hygiene applications. An optional battery pack provides up to 14 hrs of run time on a full charge.

Model 430 Features

  • Well-suited for portable, low power monitoring applications.
  • 2.4 Kg weight and 10 x 18 x 26cm in size
  • Proven UV Absorption method used in Teledyne API’s range of popular Industrial Ozone products
  • High quality construction
  • Rugged and lightweight ABS polycarbonate chassis with handle
  • Wide operating range 0 – 100 ppb to 0 – 20,000 ppb (user-selectable) and Lower Detectable Limit < 2 ppb
  • US EPA Federal Equivalent Method EQOA-1015-229 certification.

Download Specifications

The post TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) appeared first on Thomson Environmental Systems.

]]>
MesaLabs Defender Series https://thomsongroup.com.au/product/mesalabs-defender-series/ Tue, 25 Sep 2018 09:49:53 +0000 https://thomsongroup.com.au/?post_type=product&p=16467 MesaLabs Defender Series are the industry standard for accurate, reliable and portable Primary calibrators 3 models for 3 flow standards: • 1% Accuracy Volumetric • Low: 5-500ccm • Medium: 50-5,000ccm • High: 300-30,000ccm Defender 510 and Defender 520 Volumetric accuracy: ± 1% of reading Three flow ranges: Low: 5 – 500 ccm; Medium: 50 – […]

The post MesaLabs Defender Series appeared first on Thomson Environmental Systems.

]]>
MesaLabs Defender Series are the industry standard for accurate, reliable and portable Primary calibrators
3 models for 3 flow standards:
• 1% Accuracy Volumetric
• Low: 5-500ccm
• Medium: 50-5,000ccm
• High: 300-30,000ccm

Defender 510 and Defender 520

  • Volumetric accuracy: ± 1% of reading
  • Three flow ranges: Low: 5 – 500 ccm; Medium: 50 – 50,000 ccm; High: 300 – 30,000 ccm
  • Defender 510 volumetric primary flow standard
  • Defender 520 enhanced volumetric primary flow standard
  • Documents temperature and pressure for enhanced audit trail.

Defender 530+

  • Three flow ranges: Low: 5 – 500 ccm; Medium: 50 – 50,000 ccm; High: 300 – 30,000 ccm
  • Volumetric accuracy: ± 0.75% of reading
  • Primary flow standard
  • Standardised accuracy: ± 1% of reading
  • Swagelok fittings

Download Brochure

Technical Specifications

  • Approximate Time per Reading: 1-15 seconds
  • Reading Styles (with averaging function userselectable from 1 to 100 measurement): Single (manual), Continuous or Burst
  • Gas Compatibility: Non-corrosive, non-condensing, less than 70% humidity
  • Flow Modes: Pressure or Suction
  • Measurement Cell Style: Integrated
  • AC Adapter/Charger: 12V DC, >250ma, 2.5 mm center positive
  • Battery System: 6V rechargeable, sealed lead-acid, 6-8 hrs typical operation
  • Battery Operational Time (5 cycles/min): 3 hrs backlight on, 8 hrs backlight off
  • Pressure and Suction Fittings: 1/4” ID Swagelok® compression fittings, 3/8” fittings on High Model
  • Warranty: 1 year; battery 6 months
  • Storage Temperature: 0-70°C
  • Ambient Humidity: 0-70%, non-condensing
  • Operating Pressure (Absolute): Atmospheric, 15 PSI Max
  • Display: Backlit graphical LCD
  • Data Port (for PC interface): Serial (RS-232)
  • Data Cable (for PC interface): 1 meter (Defender Data Port to PC included)
  • Protective Case: Pelican case available
  • Dimensions (H x W x D): 5.5” x 6” x 3” / 140 x 150 x 75 mm
  • Weight: 29 oz / 820 g
Model Defender 510 Defender 520 Defender 530+
 Flow Ranges Low: 5-500 ccm

Medium: 50-5,000 ccm

High: 300-30,000 ccm

Low: 5-500 ccm

Medium: 50-5,000 ccm

High: 300-30,000 ccm

Low: 5-500 ccm

Medium: 50-5,000 ccm

High: 300-30,000 ccm

Volumetric Accuracy 1% 1% 0.75%
Standardized Accuracy N/A N/A 1%
User Selectable Volumetric Units mL/min, L/min, cc/min, cf/min mL/min, L/min, cc/min, cf/min mL/min, L/min, cc/min, cf/min
User Selectable Standardized Units N/A N/A smL/min, sL/min, scc/min, scf/ min
User Selectable Temperature Units N/A °C, °F °C, °F
User Selectable Pressure Units N/A mmHg, PSI, kPa mmHg, PSI, kPa
Pressure Accuracy N/A ± 3.5 mmHg (typical) ±7.0 mm (max) ± 3.5 mmHg (typical) ±7.0 mm (max)
Temperature Accuracy N/A ± 0.8 °C (typical) ± 1.3 °C (max) ± 0.8 °C (typical) ± 1.3 °C (max)
Industry Applications Industrial Hygiene, Air Quality Industrial Hygiene, Air Quality Manufacturing, Air Quality, Personal Gas Sampling
Pressure and Suction Fittings 1/4″ ID Hose Barb 1/4″ ID Hose Barb 1/4″ ID Swagelok ® compression fittings, 3/8″ fittings on High Model

The post MesaLabs Defender Series appeared first on Thomson Environmental Systems.

]]>
MesaLabs DryCal 800 Gas Flow Calibrator https://thomsongroup.com.au/product/mesalabs-drycal-800/ Tue, 25 Sep 2018 09:43:58 +0000 https://thomsongroup.com.au/?post_type=product&p=16461 The DryCal 800 is a positive displacement primary piston prover for gas flow measurements in either pressure or vacuum applications. It combines the accuracy of a primary standard with unequalled speed and convenience. It meets the most stringent laboratory and industrial process control requirements, making it an ideal solution. DryCal 800: Primary Piston Prover A […]

The post MesaLabs DryCal 800 Gas Flow Calibrator appeared first on Thomson Environmental Systems.

]]>
The DryCal 800 is a positive displacement primary piston prover for gas flow measurements in either pressure or vacuum applications. It combines the accuracy of a primary standard with unequalled speed and convenience. It meets the most stringent laboratory and industrial process control requirements, making it an ideal solution.

DryCal 800: Primary Piston Prover
A positive displacement primary piston prover for gas flow measurement
• ±15% Accuracy Primary Flow Standard
• NVLAP accredited, ISO 17025
• Proven DryCal technology features a near frictionless piston and flow cell design that provides highly accurate, liquid free and reliable gas flow readings independent of the gas species measured.
• 5 interchangeable flow cells available to range from 0.5ccm to 100SLPM.
• User friendly Drycal Pro Software to view and plot data in real time and export.
• LCD touch screen
• Variable Area Gas flow meter Calibration
• Flow bench systems available for specific applications
• Integrator Pro to allow fast and accurate calibration of MFCs and MFMs
• Firmware upgrade via communication port- no disassembly required.

Download Brochure

Technical Specifications

  • 0.5 sccm – 100 slpm Flow Range.
  • 0.25% Measurement Uncertainty (0.5 – 50 sccm).
  • 0.15% Measurement Uncertainty (5 – 100,000 sccm).
  • 5 Interchangeable Flow Cells.
  • Proven DryCal Technology – Accurate and reliable gas flow readings independent of gas species measured.
  • Innovative – 100:1 turndown ratio; accurately measuring flow rates as low as 0.5 sccm.
  • Simple touch screen operation.
  • Quality and Expertise — 0.08% Scope of Accreditation for gas flow by NVLAP of NIST; Over 20 years of experience providing training, installations, system consulting, and custom solutions.
  • 1/4″ ID Swagelok® tube compression fitting (1/8″ fittings Model 800-3) (1/2″ outlet fitting Model 800-44)
  • Serial (RS-232) and USB.
  • CE / RoHS compliance
Model              Flow Ranges Standardized Accuracy  Time per Reading  Weight
200-800-DCB-R
  • DryCal 800 Base (RoHS)
  • Houses the timing circuitry and fits any one of the five interchangeable flow cells
200-800-3

50 mLPM

 0.5-50 sccm +/-0.25%, +/-0.002 sccm  1-60 seconds  80 oz / 2300 g
200-800-10

500 mLPM

 5-500 sccm +/-0.15%  3-135 seconds  85.1 oz / 2412.5 g
200-800-24

5 LPM

 50-5,000 sccm +/-0.15%  3-90 seconds  86 oz / 2439.3 g
200-800-44

50 LPM

 500-50,000 sccm +/-0.15%  1-35 seconds  88.4 oz / 2507 g
200-800-75

100 LPM

1-100 slm +/-0.15% 1-50 seconds 160 oz / 4535 g

The post MesaLabs DryCal 800 Gas Flow Calibrator appeared first on Thomson Environmental Systems.

]]>
MesaLabs Air Flow Calibration https://thomsongroup.com.au/product/mesa-air-flow-calibration/ Tue, 25 Sep 2018 09:22:35 +0000 https://thomsongroup.com.au/?post_type=product&p=16440 DeltaCal The BGI deltaCal® is a simple-to-use, NIST Traceable Standard for volumetric air flow, barometric pressure, and ambient temperature. The deltaCal is a venturi based system with built-in compensation for changes in ambient temperature and pressure. All deltaCal systems are built and tested at Mesa which is a NIST traceable Calibration Laboratory. To begin calibration, […]

The post MesaLabs Air Flow Calibration appeared first on Thomson Environmental Systems.

]]>

DeltaCal
The BGI deltaCal® is a simple-to-use, NIST Traceable Standard for volumetric air flow, barometric pressure, and ambient temperature.

The deltaCal is a venturi based system with built-in compensation for changes in ambient temperature and pressure. All deltaCal systems are built and tested at Mesa which is a NIST traceable Calibration Laboratory.

To begin calibration, simply replace the sampler inlet head on any U.S. EPA PM10 and PM2.5 designated samplers with the deltaCal sampling head. Additionally, the deltaCal is useable with any air sampler in the 1.5 to 19.5 LPM range with an accessory adapter. The higher flow DC100 Model allows for calibration of European standard PM samplers. The lower flow DC200 Model allows for calibration of nephelometers and other light scattering particulate monitors.

  • DC1 Model provides flow range of 1.5-19.5 LPM
  • DC100 Model provides flow range of 10 – 60 LPM
  • DC200 Model provides flow range of 0.3-3.5 LPM
  • IST-traceable accuracy ≤ 1% of flow reading<
  • Continuous uninterrupted output display of all parameters

Download Specifications
 

 

TetraCal
NIST Traceable standard for volumetric air flow, barometric pressure and ambient temperature
For calibration of:
– Environmental and industrial hygiene air sampling instruments
– Particulate samplers to US EPA requirements
• Simple on/off design
• Use on any sampler in the range 0.1 – 60 LPM
• Portable Venturi based calibrator
• 20 hr battery life
• Optional external temperature probe
• Use in the field or laboratory

Download Specifications

The post MesaLabs Air Flow Calibration appeared first on Thomson Environmental Systems.

]]>