Gas Monitors | Discover Why You Need One https://thomsongroup.com.au/product-category/gases/ Thu, 26 Jun 2025 04:26:29 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Gas Monitors | Discover Why You Need One https://thomsongroup.com.au/product-category/gases/ 32 32 Model 3110​​ / 3110P / 3110XL https://thomsongroup.com.au/product/model-3110-3110p-3110xl/ Thu, 26 Jun 2025 04:18:51 +0000 https://thomsongroup.com.au/?post_type=product&p=21118 The Model 3110 represents the new generation of portable trace and percent oxygen analysis capabilities. It combines a rugged, portable analyzer with the high reliability of trace and percent level sensors. This ensures highly accurate ppm/ percent oxygen readings in a variety of background gases (including hydrocarbons). In addition, the microprocessor-based electronics provide accurate, high […]

The post Model 3110​​ / 3110P / 3110XL appeared first on Thomson Environmental Systems.

]]>
The Model 3110 represents the new generation of portable trace and percent oxygen analysis capabilities. It combines a rugged, portable analyzer with the high reliability of trace and percent level sensors. This ensures highly accurate ppm/ percent oxygen readings in a variety of background gases (including hydrocarbons). In addition, the microprocessor-based electronics provide accurate, high resolution readings and easy-to-use features.​

3110: 0-10ppm to 10,000ppm with Micro-Fuel Cell

3110P: 0-1% to 0-25% with Micro-Fuel Cell

3110XL: 0-2ppm to 10,000ppm with Micro-Fuel Cell

Features

    • Ranges: 0-10 ppm to 0-10,000 ppm with 0-25% over-range
    • Analyzer is intrinsically safe, FM-approved for Class I Div 1 Groups D and ATEX-approved for Zone 0 (ia) IIC*
    • Sensor: Micro-fuel Cell Class B-2C
    • Calibration: In ambient air or with a certified span gas
    • System power requirements: AC power for battery recharge circuit of two current limited rechargeable NiCad batteries,
    • 0-1V analog output​​
    • Digital meter readout
    • Steel quick-disconnect fittings with nylon cell block; mating set (3) of male fittings (vent, sample, calibration); calibration hose
    • Carrying case (P/N: E834) – black, durable plastic, foam interior, or (P/N: E836) larger case for a unit with a sample system​

    *third-party approved only for O2 levels below 20.9%

Applications

  • Air separation and liquefaction
  • Pure gaseous hydrocarbon stream monitoring
  • Semiconductor manufacturing
  • Protective atmosphere blanketing of primary liquid feedstocks​ and flammable liquids
  • Process analysis of gaseous monomers – vinyl chloride, propylene, butadiene, isoprene or ethylene
  • Gas purity certification
  • Glove box or pipeline leak detection
  • Natural gas treatment and transmission
  • Catalyst protection
  • Inert gas welding of exotic metals
  • Wave and re-flow soldering
  • Heat treating and bright annealing
  • Nuclear fuel processing and isotope separation
  • Analysis of chemical reactions
  • Head space gas analysis
  • Crystal growth
  • Plastics manufacturing

Download Brochure

The post Model 3110​​ / 3110P / 3110XL appeared first on Thomson Environmental Systems.

]]>
Model 7500za-7600za https://thomsongroup.com.au/product/model-7500za-7600za/ Thu, 26 Jun 2025 03:48:55 +0000 https://thomsongroup.com.au/?post_type=product&p=21114 The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design. Features 4-digit indication, LCD with CFL Backlight Follow & […]

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design.

Features

  • 4-digit indication, LCD with CFL Backlight
  • Follow & Hold output signal control (during calibration)
  • Remote range change control
  • 85-264 VAC 50/60 Hz power
  • Simultaneous measurement of up to multiple components, one or two ranges each
  • In-depth, valuable analyzer functions attainable from the front panel user interface buttons
  • Range ID signals
  • Instrument or calibration error contact outputs
  • 19” rack configuration with optional slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine-tune analyzer performance.

Applications

  • Emission Gas Analysis
  • Food and Beverage CO2 Analysis
  • Industrial Bulk Gas Analysis.

Download Brochure

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
TECORA Isokinetic G8 https://thomsongroup.com.au/product/tecora-isoskinetic-g8/ Fri, 13 Jun 2025 00:15:07 +0000 https://thomsongroup.com.au/?post_type=product&p=21074 After more than 40 years of experience with automatic isokinetic sampling systems the 3rd generation isokinetic sampler, ISOKINETIC G8, is the most advanced sampler in the market, updated to all EN and EPA standards as well as fully compliant to the metrological chain requirements mentioned in the standard ISO17025. With new digital architecture and improved […]

The post TECORA Isokinetic G8 appeared first on Thomson Environmental Systems.

]]>
After more than 40 years of experience with automatic isokinetic sampling systems the 3rd generation isokinetic sampler, ISOKINETIC G8, is the most advanced sampler in the market, updated to all EN and EPA standards as well as fully compliant to the metrological chain requirements mentioned in the standard ISO17025.

With new digital architecture and improved automation, the G8 improves on the very stable and easy to use G4 platform and user interface.

Warning and alarm messages are sent to your phone via G8 app, so you have total control any time, anywhere!

New internal components provide significant weight and footprint reductions for better handling/transportability which improves user productivity in sampling platforms with limited space.

Features

  • Connection with online analyzer to acquire CO2 and O2 data for an accurate and real time gas density calculation (optional). Also other pollutants can be archived in a dedicated report
  • Advanced digital high resolution differential pressure sensors with near zero drift. High temperature stability over the sampling period
  • Fixed point stack gas speed measure as required from ISO16911-1
  • Automatic unattended sensor verification
  • Wide resistive touch screen. any type of touching material can manage it (gloves, pen, etc). All the informations are available in a clear high res view
  • Connection with swirl angle meter to verify the flow as required from ISO16911-1 (optional)
  • Background diagnostic test procedure to ensure total efficiency during sampling
  • USB interface to download data
  • Total isokinetic control within the standard limits with very fast response and high flow stability even in the most unstable stack gas speed conditions
  • Volume measurement with dry gas meter
  • Sampling flow measurement with venturi flow meter
  • In-stack temperature and velocity measurement
  • Wide duct library to archive all site data
  • Data logger function with saving data on internal memory or external USB key (supplied with the instrument)
  • Very high MTBF which results in low maintenance and low spares cost
  • All sensors can be calibrated as required from ISO17025
  • Auto check at starting
  • Leak test in line during sampling using an O2 sensor
  • Log measurements and alarms
  • Automatic re-start in case of flue gas velocity alarm.

Download Brochure

The post TECORA Isokinetic G8 appeared first on Thomson Environmental Systems.

]]>
Prismatic 3 https://thomsongroup.com.au/product/prismatic-3/ Tue, 27 May 2025 02:18:00 +0000 https://thomsongroup.com.au/?post_type=product&p=20789 TIGER OPTICS™ Prismatic 3™ laser-based, multi-species trace gas analyzer, provides a critical tool for use in research and industrial applications, where real-time, on-line gas monitoring is essential. The Prismatic 3 is ideally suited for fuel-cell hydrogen purity monitoring throughout the entire hydrogen supply chain—from production to transportation and storage to the fueling station. This compact, […]

The post Prismatic 3 appeared first on Thomson Environmental Systems.

]]>
TIGER OPTICS™ Prismatic 3™ laser-based, multi-species trace gas analyzer, provides a critical tool for use in research and industrial applications, where real-time, on-line gas monitoring is essential. The Prismatic 3 is ideally suited for fuel-cell hydrogen purity monitoring throughout the entire hydrogen supply chain—from production to transportation and storage to the fueling station.

This compact, CRDS-based analyzer for the detection of H2O, CO, CO2 and CH4 from parts-per-billion to parts-per-million levels to ensure purity requirements in line with SAE J2719 and ISO 14687:2019.

Prismatic 3 is easy to install and operate with integrated touchscreen and intuitive graphical user interface to allow efficient data trending and analysis. The cost of ownership is extremely low, with no calibration, spare parts or utility gases required.

The Prismatic 3 features:

  • Simultaneous parts-per-billion detection of CO, CO2, H2O and CH4
  • Ideal analyzer to meet Hydrogen purity requirements of SAE J2719 and ISO 14687:2019
  • Powerful Cavity Ring-Down Spectroscopy (CRDS) technology
  • Low Cost of Ownership: no calibration or utility gas requirements
  • Easy to install and use per ASTM Standard Test Method D7941

Applications

  • Air Separation Units & Nitrogen Plants
  • Gas Quality Control
  • Gaseous CRMs & Calibration Gas Mixtures
  • Greenhouse Gas Monitoring
  • High-Purity Gases & Systems
  • Hydrogen Fuel Cells
  • Research & Development

Data Sheet

The post Prismatic 3 appeared first on Thomson Environmental Systems.

]]>
Clarity Multi-Gas Module https://thomsongroup.com.au/product/clarity-multi-gas-module/ Thu, 06 Mar 2025 22:54:30 +0000 https://thomsongroup.com.au/?post_type=product&p=20698 The Clarity Multi-Gas Module expands the capabilities of the Node-S, enabling real-time measurement of CO, O₃, NO₂, NO, and NOx — five key pollutants that impact air quality and public health. Whether monitoring urban pollution, industrial emissions, or transportation corridors, this compact, all-in-one sensor provides high-quality data without the complexity of multiple instruments. Designed for […]

The post Clarity Multi-Gas Module appeared first on Thomson Environmental Systems.

]]>
The Clarity Multi-Gas Module expands the capabilities of the Node-S, enabling real-time measurement of CO, O₃, NO₂, NO, and NOx — five key pollutants that impact air quality and public health. Whether monitoring urban pollution, industrial emissions, or transportation corridors, this compact, all-in-one sensor provides high-quality data without the complexity of multiple instruments.

Designed for effortless deployment, the Multi-Gas Module features a weatherproof, UV-resistant enclosure and modular mounting for quick installation on both vertical and horizontal poles. With Clarity’s plug-and-play Add-On Module design, the Multi-Gas Module leverages the solar-powered operation and built-in cellular connectivity of the Node-S — even when paired with the Wind Module.

Multi-Gas Module use cases

CO and wildfires

  • CO is a by-product of combustion, emitted by both wildfires and urban sources
  • Wildfires produce significantly more PM2.5 per unit of CO than urban sources
  • The PM2.5-to-CO ratio helps distinguish wildfire smoke from urban pollution.

NOₓ and traffic

  • High NO and NO₂ levels identify traffic-related pollution hotspots
  • A higher NO-to-NO₂ ratio indicates fresh emissions near the source, while a lower ratio suggests chemical transformation as the air moves further away.

O₃ non-attainment and smog formation

  • Quantify diurnal pattern of NOx (morning, evening peaks) and O3 (afternoon peak)
  • Elevated NOₓ and O₃ together signal strong photochemical activity and smog formation.

Download Specifications

Case Studies

The post Clarity Multi-Gas Module appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) https://thomsongroup.com.au/product/teledyne-api-model-t700u-dynamic-dilution-calibrator-tapi/ Wed, 30 Oct 2024 01:43:08 +0000 https://thomsongroup.com.au/?post_type=product&p=20628 The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers.  Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources. In addition to the features of the Model T700, the Model T700U is […]

The post TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers.  Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.

In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements.  The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators.  To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or “fractional” mode, for producing accurate ozone levels down to 3 ppb.  To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.​

The Model T700U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

Features

  • Stable and accurate ozone output to 3 ppb
  • Stable and accurate Gas Phase Titration (GPT) to 3 ppb NO2
  • Built-in photometer, ozone generator, and GPT chamber
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 12 independent timers for sequences
  • Nested sequences (up to 5 levels)
  • Software linearization of mass flow controllers (MFC)
  • 4 calibration ports (configurable for single or multi-blend gases)
  • 3rd MFC for wide dynamic range (optional)
  • Glass gas phase titration chamber (GPT)
  • Inlets for external ozone reference sources
  • Two-year warranty.

Download Specifications

The post TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T701H Zero Air Generator https://thomsongroup.com.au/product/teledyne-api-t701h-zero-air-generator-tapi/ Tue, 29 Oct 2024 21:59:58 +0000 https://thomsongroup.com.au/?post_type=product&p=20621 The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and […]

The post TELEDYNE API T701H Zero Air Generator appeared first on Thomson Environmental Systems.

]]>
The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.

The T701H is a fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with highly sensitive analyzers in ambient background and trace level applications. The T701H includes a dewpoint sensor, an oil and diaphragm-free pump, scrubbers to remove SO2, NO, NO2, O3, H2S and NH3, plus high performance scrubbers to remove CO and Hydrocarbons.

The regenerative, heatless dryer removes water and produces output with a dew point less than -40ºC (up to 30 SLPM flow rate). The system’s pressure, temperature, and dewpoint values are all continuously monitored, which allows a microcontroller to adjust the pump cycling frequency, valve timing, and heater power for optimal performance

Features

  • Modbus Connectivity
  • Trace Level output purity
  • Dewpoint Sensor
  • Once/year maintenance interval
  • Regenerative, heat-less dryer for maintenance-free water removal
  • Long-life scrubbers for SO2, NO, NO2, O3, H2S and NH3
  • High performance CO/Hydrocarbon scrubber
  • Automatic water drain
  • Automatic pump control with demand tank
  • Two-year warranty.

Download Specifications

The post TELEDYNE API T701H Zero Air Generator appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T102 TRS https://thomsongroup.com.au/product/teledyne-api-t102-trs/ Wed, 16 Oct 2024 06:13:43 +0000 https://thomsongroup.com.au/?post_type=product&p=20594 ​The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur (TRS) at levels commonly required for ambient air monitoring. The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater […]

The post TELEDYNE API T102 TRS appeared first on Thomson Environmental Systems.

]]>
​The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur (TRS) at levels commonly required for ambient air monitoring.

The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

The Model T102 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

Features

  • Ranges: 0-50 ppb to 0-10 ppm TRS and up to 20 ppm SO2, user selectable
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Auto zero system
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty

Applications

  • Ambient Air Monitoring
  • CEMS – Stack Air Monitoring​​
  • Fenceline Air Monitoring
  • Semiconductor

Download Specifications

The post TELEDYNE API T102 TRS appeared first on Thomson Environmental Systems.

]]>
MIRA Ultra N2O/CO https://thomsongroup.com.au/product/mira-ultra-n2o-co/ Wed, 04 Sep 2024 04:33:13 +0000 https://thomsongroup.com.au/?post_type=product&p=20386 MIRA Ultra N2O/CO, based on Aeris’ revolutionary, miniature laser-based sensor engine, achieves sub-ppb sensitivity and accuracy in seconds. It is the world’s first portable, high accuracy nitrous oxide and carbon monoxide gas analyzer. The Ultra N2O/CO provides extended, low drift performance via its precision temperature and pressure stabilised optical core. Portable Ultra systems can be […]

The post MIRA Ultra N2O/CO appeared first on Thomson Environmental Systems.

]]>
MIRA Ultra N2O/CO, based on Aeris’ revolutionary, miniature laser-based sensor engine, achieves sub-ppb sensitivity and accuracy in seconds. It is the world’s first portable, high accuracy nitrous oxide and carbon monoxide gas analyzer. The Ultra N2O/CO provides extended, low drift performance via its precision temperature and pressure stabilised optical core.

Portable Ultra systems can be uniquely employed for a wide range of fixed, handheld, and mobile applications.

Aeris MIRA Series analyzers operate in the middle infrared (MIR) region, achieving unparalleled specificity and sensitivity in a compact, low power consumption platform. The ability to simultaneously monitor N2O and CO in real-time with a portable analyzer enables a wide range of lab as well as field applications that were previously impractical due to traditional size, weight, power, and cost constraints. Ultra Series analyzers offer performance levels traditionally associated with much larger, more expensive gas analyzers, representing a paradigm shift in high accuracy laser-based gas analysis systems.

Key Features:

  • Temp stabilisation, sub-ppb precision and accuracy
  • Autonomous, built-in calibration or zero cycles
  • 1 or 2Hz operation
  • GPS ready for creating N2O/CO “maps”
  • Built-in WiFi, RS-232, and optional analog out
  • Lowest, 20W (average) power consumption
  • Maintenance-free sensor, user-serviceable filters
  • 2-port, differential sampling, built-in pump.

Real-Time Ambient and Source Monitoring

CO is an USEPA Priority Pollutant as well as proxy for thermo-genic CO2, while nitrous oxide is the #3 GHG that is produced in combustion processes, livestock operations, and other activities such as soil fertilisation. The MIRA Ultra N2O/CO provides a powerful new tool for lab or field studies of these important species, including regional pollution monitoring (CO) and natural gas leak tracer or soil nitrification studies (N2O).
As an absorption-based method, MIRA Ultra systems achieve high sensitivity and linearity over an extremely wide concentration range. To calibrate or re-zero, Ultra systems come equipped with two programmable sample ports and associated software that enable autonomous calibration (or rezeroing) as well as differential measurements such as in soil chamber studies. For CO, a scrubber can be installed in the analyser to provide high purity zero gas, in most cases eliminating the need for calibration gases or zero gas generators. As the core is heated to 40°C, Ultra systems are ideal for use in humid environments where condensation is of concern.

Download Specifications

The post MIRA Ultra N2O/CO appeared first on Thomson Environmental Systems.

]]>
MIRA Ultra VOC https://thomsongroup.com.au/product/mira-ultra-voc/ Wed, 04 Sep 2024 04:16:50 +0000 https://thomsongroup.com.au/?post_type=product&p=20382 Monitor Formaldehyde levels in realtime with high sensitivity and accuracy using the MIRA Ultra VOC gas analyzer. Introducing the MIRA Ultra VOC, the World’s first portable high accuracy formaldehyde gas analyzer. The Ultra VOC is based on Aeris’ revolutionary, miniature laser-based sensor engine, which achieves sub-ppb sensitivity and accuracy in seconds. The Ultra Series analyzer […]

The post MIRA Ultra VOC appeared first on Thomson Environmental Systems.

]]>
Monitor Formaldehyde levels in realtime with high sensitivity and accuracy using the MIRA Ultra VOC gas analyzer.
Introducing the MIRA Ultra VOC, the World’s first portable high accuracy formaldehyde gas analyzer.
The Ultra VOC is based on Aeris’ revolutionary, miniature laser-based sensor engine, which achieves sub-ppb sensitivity and accuracy in seconds.

The Ultra Series analyzer provides extended, low drift performance via its precision temperature stabilized optical core.

Portable Ultra systems can be uniquely employed for a wide range of fixed, handheld, and mobile applications. The low power consumption of Ultra systems makes them ideal for solar powered applications.
Aeris MIRA Series analyzers operate in the middle infrared (MIR) region, achieving unparalleled specificity and sensitivity in a compact, low power consumption platform. The ability to monitor HCHO in real-time with a portable analyzer enables a wide range of lab as well as field applications that were previously impractical due to traditional size, weight, power, and cost constraints. Ultra Series analyzers offer performance levels traditionally associated with much larger, more expensive gas analyzers, representing a paradigm shift in high accuracy laser-based gas analysis systems.

Key Features:

  • Temperature and pressure stabilized core
  • Autonomous, built-in calibration or zero cycle
  • 1 or 2Hz operation
  • GPS ready for creating HCHO “maps”
  • Built-in wifi, RS-232, and optional analog out
  • Lowest, 20W (average) power consumption
  • Maintenance-free sensor, user-serviceable filters
  • 2-port, differential sampling, built-in pump.

Real-Time Ambient and Source Monitoring

The MIRA Ultra VOC is suitable for long-term ambient monitoring applications as well as emissions quantifications studies. Common sources of formaldehyde
include including engineered wood products, glues and paints, and industrial facilities such as die-cast or plastics manufacturing plants. Comparisons with ASTM methods quantify system accuracy and linearity from ppb to ppm levels, determining absolute HCHO levels in minutes instead of hours, while eliminating wet chemistry steps and consumables (column) associated with other methods.

As an absorption-based method, MIRA Ultra systems achieve high sensitivity and linearity over an extremely wide concentration range. Ultra VOC systems come equipped with two programmable sample ports and associated software that enables autonomous calibration (or rezeroing) as well as differential measurements. As the optical core in the Ultra VOC is heated to 40°C, it is ideal for use in humid environments where the potential for condensation in the analyzer is of concern.

Download Specifications