System Integration Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-category/system-integration/ Mon, 01 Dec 2025 02:57:48 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png System Integration Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-category/system-integration/ 32 32 Gas Sample Dilution Probe SP2000-H/DIL https://thomsongroup.com.au/product/gas-sample-dilution-probe-sp2000-h-dil/ Fri, 23 Jun 2023 05:35:39 +0000 https://thomsongroup.com.au/?post_type=product&p=20021 The electrically heated M&C dilution probe is used in processes where the measuring procedure or the handling of the process gas requires the dilution of the sample gas or the component(s) to be measured, e.g. for extremely toxic gases, for moisture or emission measurement in flue gases. Since the M&C dilution probe SP2000-H/DIL is based […]

The post Gas Sample Dilution Probe SP2000-H/DIL appeared first on Thomson Environmental Systems.

]]>
The electrically heated M&C dilution probe is used in processes where the measuring procedure or the handling of the process gas requires the dilution of the sample gas or the component(s) to be measured, e.g. for extremely toxic gases, for moisture or emission measurement in flue gases.

Since the M&C dilution probe SP2000-H/DIL is based on the well-proven M&C gas sample probe SP2000H, a variety of applications requiring special filter techniques, materials, etc. can be handled without any problems with this dilution probe.

Gas sample dilution probe type SP2000‑H/DIL features:

  • external ceramic filter type S‑2K150
  • filter porosity: 2 µm
  • electrically heated external filter from 0 to 180 °C, adjustable by an integrated thermostat
  • high‑temperature limiter with reset key responding at +30 °C above Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset,
  • incl. weather protection shield with insulation
  • power: 230 V/50 Hz, 800 W
  • mounting flange: DN 65 PN 6B with G 3/4″ f connection
  • sample gas OUT: 8‑mm‑tube
  • material: SS 316Ti, ceramic, Viton®
  • Dilution ratio to be indicated with the order

Gas Sample Dilution Probe SP2000-H/DIL brochure

 

The post Gas Sample Dilution Probe SP2000-H/DIL appeared first on Thomson Environmental Systems.

]]>
Gas Sample Probe SP2000-H https://thomsongroup.com.au/product/gas-sample-probe-sp2000-h/ Thu, 04 May 2023 05:57:24 +0000 https://thomsongroup.com.au/?post_type=product&p=19972 Gas sample probe type SP2000‑H with external ceramic filter type S‑2K150, filter porosity: 2 µm, with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, high‑temperature limiter with reset key responding at +30 °C Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset, incl. weather protection shield […]

The post Gas Sample Probe SP2000-H appeared first on Thomson Environmental Systems.

]]>
Gas sample probe type SP2000‑H with external ceramic filter type S‑2K150, filter porosity: 2 µm, with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, high‑temperature limiter with reset key responding at +30 °C Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset, incl. weather protection shield with insulation, power: 230 V/50 Hz, 800 W, mounting flange: DN 65 PN 6B with G 3/4″ f connection, sample gas OUT: 1/4″ NPT f, material: SS 316Ti, ceramic, Viton®

Gas Sample Probe Series SP®Versions SP2000, SP2000-H, SP2300-H, SP2400-H range brochure

The post Gas Sample Probe SP2000-H appeared first on Thomson Environmental Systems.

]]>
TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) https://thomsongroup.com.au/product/tes-small-form-air-quality-monitoring-systems-aqms/ Fri, 03 Jul 2020 04:28:21 +0000 https://thomsongroup.com.au/?post_type=product&p=17869 Your Solution for Ambient Air Quality Monitoring Ideal for monitoring air quality outside or in workshops, TES Small Form AQMS measures key parameters: Air pollutant concentrations: PM1, PM2.5, PM4, PM10, TSP, O3, NO, NO2, O3, CO, SO2, H2S, NH3, HCHO, Cl2, HCl, VOC, CH4, CO2 – other gases available on request Meteorological parameters: temperature, pressure and relative […]

The post TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) appeared first on Thomson Environmental Systems.

]]>
Your Solution for Ambient Air Quality Monitoring

Ideal for monitoring air quality outside or in workshops, TES Small Form AQMS measures key parameters:

Air pollutant concentrations: PM1, PM2.5, PM4, PM10, TSP, O3, NO, NO2, O3, CO, SO2, H2S, NH3, HCHO, Cl2, HCl, VOC, CH4, CO2 – other gases available on request

Meteorological parameters: temperature, pressure and relative humidity

Other parameters: noise, vibration and odour

Location: GPS

The device captures data in real-time and transfers them wirelessly to a advanced web platform, for data analysis and data management, remote control of the equipment and data integration into websites, software and smart city platforms.

Small form stations are light, compact and easy to install within just a few minutes. Once the stations are connected to the Internet through several communication links on-demand (Wi-Fi, 3/4G, LoRa, Zigbee…), the hyper-localised information is automatically transferred to a secure web platform that is accessible 24 hours a day.

Customize your own Small Form AQMS that meets your needs:

Options:

  • Integrate sensors that you need
  • Choose your communication link
  • Add a back-up battery 

Accessories:

  • Solar panel and batteries
  • Heating resistance
  • Mounting plate

For a wide range of applications:

Smart cities, industrial sites, mining sites, sewage treatment plants, mines, soil remediation, refineries, workshops, warehouses, worksites, road networks, race tracks, ski, and sea resorts.

The post TES SMALL FORM AIR QUALITY MONITORING SYSTEMS (AQMS) appeared first on Thomson Environmental Systems.

]]>
Durag D-FL 220 Volume Flow Measuring System https://thomsongroup.com.au/product/durag-d-fl-220-volume-flow-measuring-system/ Fri, 09 Nov 2018 01:44:24 +0000 https://thomsongroup.com.au/?post_type=product&p=17239 For continuous, contactless volume flow measurement in dry and humid gases. Reliable, even under demanding operating conditions. Applications Continuous emission monitoring in humid and aggressive gases Continuous emission measurement in small to very large duct diameters Volume flow measurement for process control and process optimisation Features Continuous measurement of velocity and volume flow Contactless measurement  […]

The post Durag D-FL 220 Volume Flow Measuring System appeared first on Thomson Environmental Systems.

]]>
For continuous, contactless volume flow measurement in dry and humid gases. Reliable, even under demanding operating conditions.

Applications

  • Continuous emission monitoring in humid and aggressive gases
  • Continuous emission measurement in small to very large duct diameters
  • Volume flow measurement for process control and process optimisation

Features

  • Continuous measurement of velocity and volume flow
  • Contactless measurement 
  • Corrosion-resistant ultrasonic transducers
  • Measurement over the entire duct diameter
  • Automatic check functions

Key benefits

  • Certified for official emission monitoring
  • Precise measurement of gas velocity and volume flow
  • Suitable for measurement in humid and aggressive gases
  • Long life time and high availability even under extreme plant conditions
  • Low maintenance.

Industry Applications

  • Plants requiring official approval acc. to IED 2010/75/EU
  • Plants requiring compliance to 40 CFR 60 US EPA PS6
  • Emission trading of green house gases GHG acc. to 2003/87/EG / MRR
  • Power industry
  • Biomass incineration
  • Waste incineration
  • Cement industry
  • Crematories
  • Process monitoring.

Certifications

CE, QAL1 (DIN EN 14181 / DIN EN ISO 14956 / DIN EN 15267-3), MCERTS, EAC

Download Specifications

The post Durag D-FL 220 Volume Flow Measuring System appeared first on Thomson Environmental Systems.

]]>
Durag D-FL 100 Volume Flow Measuring System https://thomsongroup.com.au/product/durag-d-fl-100-volume-flow-measuring-system/ Fri, 09 Nov 2018 01:02:15 +0000 https://thomsongroup.com.au/?post_type=product&p=17237 The DURAG D-FL 100 provides a suitability-tested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts. Features Continuous measurement of velocity and volume flow Double-sided installation for measurement over the entire duct diameter or cost-saving single-sided installation  Robust and resistant probe material […]

The post Durag D-FL 100 Volume Flow Measuring System appeared first on Thomson Environmental Systems.

]]>
The DURAG D-FL 100 provides a suitability-tested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts.

Features

  • Continuous measurement of velocity and volume flow
  • Double-sided installation for measurement over the entire duct diameter or cost-saving single-sided installation 
  • Robust and resistant probe material for use in aggressive gases or at high temperatures (optional)
  • Probe individually adapted to the application
  • Automatic back purging unit (optional)
  • Automatic internal self-test

Key Benefits

  • Certified for official emission monitoring
  • Precise measurement of velocity and volume flow even under demanding operating conditions
  • Space-saving and easy single-sided installation (optional)
  • Suitable for use in potentially explosive atmospheres (optional)
  • Suitable for use in hot gases

Applications

  • Continuous emission monitoring in hot or aggressive gases
  • Continuous emission monitoring in small to large duct diameters
  • Continuous emission monitoring in explosive atmospheres
  • Volume flow measurement for process control and process optimization

Industries

  • Plants requiring official approval acc. to IED 2010/75/EU
  • Emission trading of green house gases GHG acc. to 2003/87/EG / MRR
  • Power industry
  • Incinerators with dry flue gas
  • Waste incineration
  • Cement industry
  • Crematoriums
  • Process monitoring
  • ATEX applications.

Certifications

CE, QAL1 (DIN EN 14181 / DIN EN ISO 14956 / DIN EN 15267-3), MCERTS, EAC Gost Ex Zone 2

Download Specifications

The post Durag D-FL 100 Volume Flow Measuring System appeared first on Thomson Environmental Systems.

]]>
TES Continuous Emissions Systems for VOC’s https://thomsongroup.com.au/product/vocs/ Tue, 25 Sep 2018 13:30:46 +0000 https://thomsongroup.com.au/?post_type=product&p=16568 TES offer Continuous Emissions Systems for VOC monitoring in industrial applications such as chemical processing plants, incinerators, petroleum refineries and more. Download Specifications

The post TES Continuous Emissions Systems for VOC’s appeared first on Thomson Environmental Systems.

]]>
TES offer Continuous Emissions Systems for VOC monitoring in industrial applications such as chemical processing plants, incinerators, petroleum refineries and more.

Download Specifications

The post TES Continuous Emissions Systems for VOC’s appeared first on Thomson Environmental Systems.

]]>
OPTICAL SCIENTIFIC INC (OSI) – OFS 2000 Optical Flow Sensor https://thomsongroup.com.au/product/osi-ofs-2000-optical-flow-sensor/ Tue, 25 Sep 2018 13:26:34 +0000 https://thomsongroup.com.au/?post_type=product&p=16566 The OFS-2000 has a range of 0-40m/sec and is the only flow sensor that gives a true non-contracting cross-stack flow measurement of the process. OSi’s patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average flow reading. The OFS uses EPA Method 14 approved […]

The post OPTICAL SCIENTIFIC INC (OSI) – OFS 2000 Optical Flow Sensor appeared first on Thomson Environmental Systems.

]]>
The OFS-2000 has a range of 0-40m/sec and is the only flow sensor that gives a true non-contracting cross-stack flow measurement of the process.
OSi’s patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average
flow reading.

The OFS uses EPA Method 14 approved optical scintillation technology. The optical scintillation technique relies on advanced Digital Signal Processing (DSP) electronics to “see” and measure the movement of turbulence found in a gaseous flow stream to provide highly accurate, path-averaged air velocity measurements. The accuracy of the OFS has been proven both in NIST’s wind tunnel and in numerous real-world installations.

Advantages

  • System not sensitive to dirty optics / high opacity media
  • System is non-intrusive to media flow –
  • No flow media means high temperature limits.
  • Measurement is true cross-stack line average
  • Fully meets all EPA 40CFR Parts 60 & 75
  • Unaffected by temperature, pressure, humidity, density, path length
  • Easy installation and optical alignment – once interconnect cable is run and ports are prepared, system can be connected, aligned and operating in less than 30 minutes
  • DSP-based signal processing means no analog “drift”.
  • Includes built-in continuous self-test routines to warn of potential problems before the point of failure.
  • Cross stack/duct/pipe line measurement for more accurate flow readings.
  • Measurement path 90º to stack; second plat-form not required – save $100K or more
  • Easily replaces existing ultrasonic sensors.
  • Minimal upstream/downstream diameters; typically 2 & 1, not 20 & 10 like others.
  • Long-term reliability: no blowers or moving parts; operates unattended – 24/ 7/365.
  • Ultra-low maintenance design.
  • Rugged; designed for harsh environments.
  • Built in continuous self-test diagnostics.
  • Measurement unaffected by path length & media pressure, moisture & opacity.
  • Wide versatility, NIST tested and unbeatable combination of advanced technology, high performance and proven reliability!

OFS-2000 Options

  • Order Z-Purge Option for Class I Div I/II applications.
  • Standard Control Unit is rack mount; for wall mount, order 1910-301, NEMA4 Option.
  • For custom receiver cable length, order 1910-216-nnn where “nnn” is cable length in feet (max 300).

OFS-2000 Accessories

  • 1910-431-nn Sight Glass with gaskets for media isolation (2 required, multiple models)
  • For custom receiver cable length, order 1910-216-nnn where “nnn” is cable length in feet (max 300).
  • Standard Control Unit is rack mount; for wall mount, order 1910-301, NEMA4 Option.

Download Brochure

The post OPTICAL SCIENTIFIC INC (OSI) – OFS 2000 Optical Flow Sensor appeared first on Thomson Environmental Systems.

]]>
GASMET Continuous Emissions Monitoring System (CEMS II e) https://thomsongroup.com.au/product/gasmet-continuous-emissions-monitoring-system-cems-ii-e/ Mon, 24 Sep 2018 14:36:35 +0000 https://thomsongroup.com.au/?post_type=product&p=16403 Utilising FTIR technology, the Gasmet CEMS II e Gas analyser can measure up to 50 different gas components simultaneously, including but not limited to H2O, CO2, CO, NO, NO2, N2O, SO2, HCl, HF, NH3, CH4 and speciated VOC’s. Total Organic Carbon (TOC) can also be measured with the FTIR analyzer in addition to components such […]

The post GASMET Continuous Emissions Monitoring System (CEMS II e) appeared first on Thomson Environmental Systems.

]]>
Utilising FTIR technology, the Gasmet CEMS II e Gas analyser can measure up to 50 different gas components simultaneously, including but not limited to H2O, CO2, CO, NO, NO2, N2O, SO2, HCl, HF, NH3, CH4 and speciated VOC’s. Total Organic Carbon (TOC) can also be measured with the FTIR analyzer in addition to components such as NOx.

The Gasmet CEMS II e is ideal for measuring trace concentrations of pollutants in wet, corrosive gas streams.

Its typical application is monitoring of waste incinerator or large combustion plants.

Measured gases/particulates and calibration ranges can be changed to suit the application.

All parts of the Gasmet CEMS II e can be heated up to 180 ºC.

It can be used for undiluted gases and the sample gases do not need drying beforehand.

The Gasmet CEMS II e consists of:

  • Gasmet FTIR gas analyzer
  • Gasmet industrial computer, and
  • Gasmet sampling system.

As an option the system can be equipped with ZrO2 oxygen analyzer and/or with total hydrocarbon analyzer (FID). All parts of the system are 19” rack mounted and are installed on the pull-out shelves.

The Gasmet CEMS II e includes all power connections and temperature controllers for heated lines and heated sample probe. Operation of the system is fully automatic and controlled by the Calcmet software. Additionally all functions of CEMS II e can be controlled manually.

Features

  • Low need for maintenance – 6-month maintenance interval for all certified compounds
  • No span calibrations required (automated span checks possible)
  • Hot-extractive-sampling; no sample loss or change of composition
  • Capability to water soluble compounds like HCl, HF, NH3, etc.
  • TOC (Total Organic Carbon) measured with FTIR – no need for a separated FID
  • Fully automated measurement system with comprehensive safety functions
  • Ready for future requirements – new compounds can be added without any hardware changes
  • Fully modular system built to customer specification
  • EN15267 TÜV & MCERTS certificates (QAL1)

Applications

  • Waste Incinerators
  • Waste to Energy Plants
  • Cement Kilns
  • Power Plants
  • Brick & Glass Manufacturing
  • Aluminium and Steel Smelters
  • Greenhouse Gas emissions.

Download Specifications

The post GASMET Continuous Emissions Monitoring System (CEMS II e) appeared first on Thomson Environmental Systems.

]]>
TES Direct Extractive Gaseous CEMS https://thomsongroup.com.au/product/tes-direct-extractive-gaseous-cems/ Mon, 24 Sep 2018 14:18:03 +0000 https://thomsongroup.com.au/?post_type=product&p=16396 Thomson Environmental Systems specialise in custom-designed and made Continuous Emissions Monitoring systems. Direct Extract Gaseous CEMS are relatively simple systems and economical where the sample is analysed at the actual stack levels. Concentrations are higher and therefore analysers are of lower sensitivity and require less frequent calibration to maintain accuracy. All analysers including O2 can […]

The post TES Direct Extractive Gaseous CEMS appeared first on Thomson Environmental Systems.

]]>
Thomson Environmental Systems specialise in custom-designed and made Continuous Emissions Monitoring systems.

Direct Extract Gaseous CEMS are relatively simple systems and economical where the sample is analysed at the actual stack levels. Concentrations are higher and therefore analysers are of lower sensitivity and require less frequent calibration to maintain accuracy. All analysers including O2 can be mounted at ground level. All systems designed, assembled and integrated locally to meet your specific requirements.

  • Utilises Teledyne API Medium and high level analysers
  • 2 Years Warranty on Teledyne API Analysers

ALSO available from TES

Download Specifications

The post TES Direct Extractive Gaseous CEMS appeared first on Thomson Environmental Systems.

]]>
TES Dilution Extractive Gaseous CEMS https://thomsongroup.com.au/product/tes-dilution-extractive-gaseous-cems/ Mon, 24 Sep 2018 14:13:52 +0000 https://thomsongroup.com.au/?post_type=product&p=16394 A small sample is drawn from the stack and is diluted before passing through the various system components. As a result of the dilution process there are less particulates, less moisture and lower maintenance is required. All systems designed, assembled and integrated locally to meet your specific requirements. Ideal for monitoring corrosive gases in corrosive […]

The post TES Dilution Extractive Gaseous CEMS appeared first on Thomson Environmental Systems.

]]>
A small sample is drawn from the stack and is diluted before passing through the various system components. As a result of the dilution process there are less particulates, less moisture and lower maintenance is required. All systems designed, assembled and integrated locally to meet your specific requirements.

  • Ideal for monitoring corrosive gases in corrosive sample streams
  • Utilises Teledyne API Ambient analysers
  • 2 Years Warranty on Teledyne API Analysers
  • Overlap with fenceline

ALSO available from TES

Download Specifications

The post TES Dilution Extractive Gaseous CEMS appeared first on Thomson Environmental Systems.

]]>