Teledyne API Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-brands/tapi/ Wed, 18 Jun 2025 03:57:24 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Teledyne API Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-brands/tapi/ 32 32 TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) https://thomsongroup.com.au/product/teledyne-api-model-t700u-dynamic-dilution-calibrator-tapi/ Wed, 30 Oct 2024 01:43:08 +0000 https://thomsongroup.com.au/?post_type=product&p=20628 The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers.  Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources. In addition to the features of the Model T700, the Model T700U is […]

The post TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers.  Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.

In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements.  The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators.  To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or “fractional” mode, for producing accurate ozone levels down to 3 ppb.  To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.​

The Model T700U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

Features

  • Stable and accurate ozone output to 3 ppb
  • Stable and accurate Gas Phase Titration (GPT) to 3 ppb NO2
  • Built-in photometer, ozone generator, and GPT chamber
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 12 independent timers for sequences
  • Nested sequences (up to 5 levels)
  • Software linearization of mass flow controllers (MFC)
  • 4 calibration ports (configurable for single or multi-blend gases)
  • 3rd MFC for wide dynamic range (optional)
  • Glass gas phase titration chamber (GPT)
  • Inlets for external ozone reference sources
  • Two-year warranty.

Download Specifications

The post TELEDYNE API Model T700U Trace-level Dynamic Dilution Calibrator (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T701H Zero Air Generator https://thomsongroup.com.au/product/teledyne-api-t701h-zero-air-generator-tapi/ Tue, 29 Oct 2024 21:59:58 +0000 https://thomsongroup.com.au/?post_type=product&p=20621 The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and […]

The post TELEDYNE API T701H Zero Air Generator appeared first on Thomson Environmental Systems.

]]>
The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.

The T701H is a fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with highly sensitive analyzers in ambient background and trace level applications. The T701H includes a dewpoint sensor, an oil and diaphragm-free pump, scrubbers to remove SO2, NO, NO2, O3, H2S and NH3, plus high performance scrubbers to remove CO and Hydrocarbons.

The regenerative, heatless dryer removes water and produces output with a dew point less than -40ºC (up to 30 SLPM flow rate). The system’s pressure, temperature, and dewpoint values are all continuously monitored, which allows a microcontroller to adjust the pump cycling frequency, valve timing, and heater power for optimal performance

Features

  • Modbus Connectivity
  • Trace Level output purity
  • Dewpoint Sensor
  • Once/year maintenance interval
  • Regenerative, heat-less dryer for maintenance-free water removal
  • Long-life scrubbers for SO2, NO, NO2, O3, H2S and NH3
  • High performance CO/Hydrocarbon scrubber
  • Automatic water drain
  • Automatic pump control with demand tank
  • Two-year warranty.

Download Specifications

The post TELEDYNE API T701H Zero Air Generator appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T102 TRS https://thomsongroup.com.au/product/teledyne-api-t102-trs/ Wed, 16 Oct 2024 06:13:43 +0000 https://thomsongroup.com.au/?post_type=product&p=20594 ​The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur (TRS) at levels commonly required for ambient air monitoring. The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater […]

The post TELEDYNE API T102 TRS appeared first on Thomson Environmental Systems.

]]>
​The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur (TRS) at levels commonly required for ambient air monitoring.

The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

The Model T102 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

Features

  • Ranges: 0-50 ppb to 0-10 ppm TRS and up to 20 ppm SO2, user selectable
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Auto zero system
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty

Applications

  • Ambient Air Monitoring
  • CEMS – Stack Air Monitoring​​
  • Fenceline Air Monitoring
  • Semiconductor

Download Specifications

The post TELEDYNE API T102 TRS appeared first on Thomson Environmental Systems.

]]>
Model N901 THC/CH4/NMHC https://thomsongroup.com.au/product/model-n901-thc-ch4-nmhc/ Fri, 11 Dec 2020 04:41:16 +0000 https://thomsongroup.com.au/?post_type=product&p=17981 The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas […]

The post Model N901 THC/CH4/NMHC appeared first on Thomson Environmental Systems.

]]>
The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas chromatography (GC). The instruments range and performance are tuned specifically for use in ambient air quality monitoring assessments.

The Model N901 is designed for simple operation and maintenance with a modular hardware and electronics architecture.  A long-life stainless-steel fritted filter is used at the sample intake to effectively remove particulate matter without introducing any gas-phase measurement artifacts. Instrument operation, calibration functions, chromatogram views,​ and data handling are all automated and controlled using the internal NumaView™​ Software (NVS) interface, without the need for an external PC.​

For remote connection to the N901 instrument, Teledyne API’s NumaView™ Remote PC-based Software provides a virtual interface, instrument controls, and data downloading capability to all TAPI analyzers operating NumaView™ Software.

Features

  • ​60s default cycle time
  • 25 ppb LDL (CH4, NMHC) ​
  • Fully programmable and automated directly from the instrument front panel interface
  • Modular internal hardware design for ease of maintenance
  • All internal components operate on 24VDC
  • Front panel USB connections for peripheral devices and firmware upgrades
  • Real-time chromatogram display during calibration routine
  • Real-time graphical displays of concentrations and diagnostic parameters
  • Comprehensive internal datalogging with programmable averaging periods
  • Ethernet and Serial outputs, standard
  • Analog output and digital I/O expansion (options)
  • Internal pressurized span valve for auto calibration (option)​​
Detector Flame Ionization Detector (FID)
Method Gas Chromatography with CH4 separation column
Ranges (Methane) Min: 0-5 ppm
Max: 0-1,000 ppm
Lower Detectable Limit <25 ppb (Methane); <25 ppb (Propane)
Cycle Time 60 sec (minimum), user-definable
Precision <1% of reading or 0.05 ppm (whichever is​ greater)
Linearity ​<1% of full scale
Zero Drift Zero baseline performed once per cycle
Span Drift (24hr) <1% of full scale
Sample Flow Rate 60 cc/min + 10%
Carrier Gas 50 to 70 psi​, N2 UHP Grade, Consumption 20 cc/min
Fuel Gas 50 psi ± 5%, H2 UHP Grade, Consumption 35 cc/min
FID Air 50 psi ± 5%, HC Free clean air, Consumption 350 ​cc/min
Auxiliary A​ir 70 psi ± 5%,​ Clean Dry Air, Consumption 1 cc/actuation
Included I/O 1 x Ethernet (TCP/IP)
1 x RS232
2 x front panel USB device ports​
Optional I/O Universal Analog Output Board includes (all user-definable):
4 x Isolated Voltage Outputs (5V, 10V; user-selectable)
3 x Individually Isolated Current Outputs (4-20mA)
​Digital I/O Expansion Board includes:
3 x Isolated Digital Input Controls
5 x Isolated Digital Output Controls (user-definable)
3 x Form C Relay Alarm Outputs (user-definable)
Dimensions (HxWxD) 7” x 17” x 23.5” (178 x 432 x 597 mm)
Weight 35 lbs (16 kg)
Operating Temperature 7​5-40°C
Power 100-240V, 50/60Hz, Typical Power 130W​
Warranty Two years

 

DOWNLOAD SPECIFICATIONS

The post Model N901 THC/CH4/NMHC appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API 751H Portable Zero Air Generator (TAPI) https://thomsongroup.com.au/product/teledyne-api-751h-portable-zero-air-generator-tapi/ Fri, 05 Jul 2019 05:59:40 +0000 https://thomsongroup.com.au/?post_type=product&p=17787 The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes. The […]

The post TELEDYNE API 751H Portable Zero Air Generator (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.

The 751H includes a dew point sensor, a small, powerful pump, scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3 plus high performance scrubbers to remove CO and Hydrocarbons. The regenerative heatless dryer removes water and produces output with a dew point of -20ºC (up to 10 SLPM flow rate).

The 751H features tank-less operation for real-time pressurised output without “pulsing.” A micro-controller cycles the regenerative dryer and pressurized drain and features a short cycle interval of 1 minute for high humidity applications.

Features

  • Rugged traveling case with wheels and retractable handle
  • Dew point indicator
  • Long life scrubbers for SO2, NO, NO2, O3, H2S, and NH3
  • High Performance CO/Hydrocarbon scrubber
  • Regenerative, heat-less dryer for maintenance-free water removal
  • Automatic water drain
  • Once/year maintenance interval
  • Two-year warranty.

DOWNLOAD Datasheet

The post TELEDYNE API 751H Portable Zero Air Generator (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API Model N500 CAPS NOx (TAPI) https://thomsongroup.com.au/product/teledyne-api-n500-caps-nox-tapi/ Fri, 05 Jul 2019 02:18:47 +0000 https://thomsongroup.com.au/?post_type=product&p=17784 The Teledyne API Model N500 CAPS NOx analyser is a Cavity Attenuated Phase Shift (CAPS), non-chemiluminescent NOx analyser. Using CAPS Spectroscopy to measure ‘true’ NO2, NOx and NO gases, the Teledyne API Model N500 provides an improved option for NO2, NOx and NO measurement accuracy and reduces instrument operation and maintenance costs. CAPS technology is […]

The post TELEDYNE API Model N500 CAPS NOx (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Teledyne API Model N500 CAPS NOx analyser is a Cavity Attenuated Phase Shift (CAPS), non-chemiluminescent NOx analyser.

Using CAPS Spectroscopy to measure ‘true’ NO2, NOx and NO gases, the Teledyne API Model N500 provides an improved option for NO2, NOx and NO measurement accuracy and reduces instrument operation and maintenance costs.

CAPS technology is inherently accurate and sensitive, requires less maintenance than chemiluminescence and uses less power.

Teledyne-API’s first direct true NO2 analyser, the T500U has been a popular instrument with scientists and air quality specialists looking for a faster and more precise measurement of NO2 that cannot be offered by chemiluminescence.

The Model N500 like the T500U, uses CAPS technology for true NO2 measurement but it adds the ability to measure the NO component of NOx. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component.

The new Model N500 CAPS NOx / NO2 / NO analyser is available exclusively in Australia and New Zealand through Thomson Environmental Systems.

Download Specifications

Learn more

The post TELEDYNE API Model N500 CAPS NOx (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) https://thomsongroup.com.au/product/teledyne-api-model-430-portable-fem-ozone-analyzer/ Mon, 19 Nov 2018 02:31:41 +0000 https://thomsongroup.com.au/?post_type=product&p=17319 The Model 430 03 monitor uses the proven UV Absorption principle, producing accurate and stable O3 measurements. The small footprint and quiet operation make it extremely useful for ambient air and indoor air quality, surveying, and industrial hygiene applications. Model 430 carries US EPA Federal Equivalent Method EQOA-1015-229 certification. The Model 430 Compact O3 Analyzer […]

The post TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model 430 03 monitor uses the proven UV Absorption principle, producing accurate and stable O3 measurements.
The small footprint and quiet operation make it extremely useful for ambient air and indoor air quality, surveying, and industrial hygiene applications.

Model 430 carries US EPA Federal Equivalent Method EQOA-1015-229 certification.

The Model 430 Compact O3 Analyzer uses the proven UV Absorption principle, to produce accurate and stable O3 measurements. The robust design and low power consumption makes it ideal for portable monitoring applications such as rural and remote monitoring, saturation studies, and atmospheric research.

The small footprint and quiet operation make it extremely useful for indoor air quality, surveying, and industrial hygiene applications. An optional battery pack provides up to 14 hrs of run time on a full charge.

Model 430 Features

  • Well-suited for portable, low power monitoring applications.
  • 2.4 Kg weight and 10 x 18 x 26cm in size
  • Proven UV Absorption method used in Teledyne API’s range of popular Industrial Ozone products
  • High quality construction
  • Rugged and lightweight ABS polycarbonate chassis with handle
  • Wide operating range 0 – 100 ppb to 0 – 20,000 ppb (user-selectable) and Lower Detectable Limit < 2 ppb
  • US EPA Federal Equivalent Method EQOA-1015-229 certification.

Download Specifications

The post TELEDYNE API Model 430 Portable FEM Ozone Analyzer (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T100 SO2 Series (TAPI) https://thomsongroup.com.au/product/teledyne-api-t100-so2-series/ Wed, 26 Sep 2018 10:35:32 +0000 https://thomsongroup.com.au/?post_type=product&p=16703 The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV […]

The post TELEDYNE API T100 SO2 Series (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.

Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software.

The Model T100 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.

Download Specifications

The post TELEDYNE API T100 SO2 Series (TAPI) appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T101 H2S https://thomsongroup.com.au/product/teledyne-api-t101/ Wed, 26 Sep 2018 10:29:35 +0000 https://thomsongroup.com.au/?post_type=product&p=16701 ​The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring. The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2

The post TELEDYNE API T101 H<sub>2</sub>S appeared first on Thomson Environmental Systems.

]]>
​The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.

The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ S​oftware. Download Specifications

The post TELEDYNE API T101 H<sub>2</sub>S appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API T500U NO2 CAPS (TAPI) https://thomsongroup.com.au/product/teledyne-api-t500u-no2-caps/ Wed, 26 Sep 2018 10:22:03 +0000 https://thomsongroup.com.au/?post_type=product&p=16699 The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package. The […]

The post TELEDYNE API T500U NO2 CAPS (TAPI) appeared first on Thomson Environmental Systems.

]]>
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.

The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescence instruments. The CAPS measurement approach also reduces maintenance items, and removes the nee​d for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expec​​​ted maintenance interval of one year under typical ambient monitoring conditions.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

Features

  • USEPA Approved analyzers with a variety of ranges.
  • Touch screen with a selectable format and predictive diagnostics and internal logging.
  • Free remote software for total control
  • User-friendly engineering for operation and maintenance.
  • True, Direct NO2 measurement
  • Extended maintenance interval
  • No converter or reagent required
  • No known ambient air interferences
  • Fast response
  • Exceptional measurement sensitivity
  • Low power consumption
  • Ranges: 0-5 ppb to 0-1 ppm, user selectable
  • Adaptive signal filtering optimizes response time
  • Temperature & Pressure compensation
  • All standard T-Series platform features
  • Two-year warranty

Download Specifications
Download Brochure

The post TELEDYNE API T500U NO2 CAPS (TAPI) appeared first on Thomson Environmental Systems.

]]>