NO Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-tag/no/ Thu, 26 Jun 2025 04:07:21 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png NO Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-tag/no/ 32 32 Model 7500za-7600za https://thomsongroup.com.au/product/model-7500za-7600za/ Thu, 26 Jun 2025 03:48:55 +0000 https://thomsongroup.com.au/?post_type=product&p=21114 The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design. Features 4-digit indication, LCD with CFL Backlight Follow & […]

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design.

Features

  • 4-digit indication, LCD with CFL Backlight
  • Follow & Hold output signal control (during calibration)
  • Remote range change control
  • 85-264 VAC 50/60 Hz power
  • Simultaneous measurement of up to multiple components, one or two ranges each
  • In-depth, valuable analyzer functions attainable from the front panel user interface buttons
  • Range ID signals
  • Instrument or calibration error contact outputs
  • 19” rack configuration with optional slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine-tune analyzer performance.

Applications

  • Emission Gas Analysis
  • Food and Beverage CO2 Analysis
  • Industrial Bulk Gas Analysis.

Download Brochure

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
GasEye Extractive https://thomsongroup.com.au/product/gaseye-extractive/ Tue, 18 Jun 2024 03:56:26 +0000 https://thomsongroup.com.au/?post_type=product&p=20185 The GasEye Extractive is a versatile gas analyzing tool for industrial process applications. A process gas sample is continuously fed into the analyzer where it is analyzed in real-time utilizing laser absorption spectroscopy. It can be configured to operate in the near-infrared (NIR), mid-infrared (MIR), and infrared (IR) wavelength range thereby allowing to analyze the […]

The post GasEye Extractive appeared first on Thomson Environmental Systems.

]]>
The GasEye Extractive is a versatile gas analyzing tool for industrial process applications. A process gas sample is continuously fed into the analyzer where it is analyzed in real-time utilizing laser absorption spectroscopy.

It can be configured to operate in the near-infrared (NIR), mid-infrared (MIR), and infrared (IR) wavelength range thereby allowing to analyze the majority of gases of interest in the industrial process monitoring.

GasEye Extractive analyzer is assembled in a 19” RACK IP20 or wall-mounted IP66 enclosure.

Applications
  • Safety monitoring
  • Process Control
  • Custody transfer.
Industries
  • Chemical industry
  • Petrochemical industry
  • Food industry.
Features
  • Sample temperature: 0 – 200°C
  • Real time sensing: response time below 1s
  • High selectivity: automatic compensation for interference effect from other constituents in the gas sample
  • High sensitivity: detection limits down to ppb range
  • Maintenance free: equipped with a self-calibrating feature, no field calibration necessary
  • ATEX version available
Most common application
Model: Minimum range: Typical Application:
GasEye Extractive H2O 0 – 5 ppmv Moisture in NG, LNG, H2
GasEye Extractive H2S 0 – 10 ppmv H2S in NG, LNG, H2
GasEye Extractive H2 0 – 10 vol% Hydrogen applications
GasEye Extractive CO/CO2/CH4 CO: 0 – 1 ppmv
CO2: 0 – 2 ppmv
CH4: 0 – 10 ppmv
Hydrogen purity PSA/PSA+
GasEye Extractive HCOOH/HCHO/NH3 HCOOH: 0 – 1 ppmv
HCHO: 0 – 1 ppmv
NH3: 0 – 1 ppmv
Hydrogen purity
GasEye Extractive H2/O2 H2: 0 – 10 vol%
O2: 0 – 100 ppmv
Hydrogen applications
Operating principle

GasEye Extractive is a laser spectrometer that uses single line molecular absorption spectroscopy. A semiconductor laser emits a beam of infrared light which passes through the process and impinges the detector on the receiver side. When the target gas is present the light intensity changes and this can be used to determine the concentration of the measured specimen. The wavelength of the radiation emitted by the laser is chosen to match the specific absorption line wavelength of the gas. The laser continuously scans this single absorption line with a very high spectral resolution. The measurement is free of cross-interferences since the laser light is absorbed very selectively by only one specific line in the scanned spectral range.

19″ RACK VERSION
 

GasEye Extractive 19″ RACK analyzer is assembled in a standard 19-inch rack 4U version.

It exists in several various configurations from single gas to multi gas applications.

Specification:
Dimensions: width x height: 482 mm x 177 mm
length: 650 mm
Weight: 35 kg (for the model with multipass cell, vacuum pump, and safety valves)
Gas connection: 6 mm tubing
Degree of protection: IP20 to EN 60529
Materials:
Housing: aluminium
Internal process cell: stainless steel 316
Cell window: sapphire
 Climatic conditions
Ambient temperature: 5ºC to 40ºC
Ambient pressure: 800 – 1200 hPa
Ambient humidity: RH < 90%, non-condensing
Measurement conditions
Sample gas pressure: 0.05 – 5 barG
Sample gas temperature: ambient
Sample gas flow: 0.5 – 20 Ndm3/min
Safety:
Low Voltage Directive (LVD) 2014/35/EU PN-EN 60825-1:2014-11 – Safety of laser products – Part 1: Equipment classification and requirements
PN-EN 61010-1:2011 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements
EMC Directive 2014/30/EU EN 61326-1:2013-6 – Electrical equipment for measurement, control and laboratory use
RoHS Directive 2011/65/EU

 

WALL MOUNTED VERSION

The GasEye Extractive Wall Mounted type analyzer exists in general purpose and hazardous area configuration (version Ex1). It exists in several various configurations from single-gas to multi-gas applications. The system is IP66 rated with ambient temperature ranges from -30ºC to +60ºC and can be mounted outside without a need for a container.

GasEye Extractive Ex1 provides Ex p (purge and pressurization) type of explosion protection. Ex p pressurized equipment is the technique of guarding against the ingress of the external atmosphere into an enclosure by maintaining a protective gas therein at a pressure above that of the external atmosphere. The overpressure is maintained either with or without a continuous flow of the protective gas.

 

Specification:
Dimensions: width x height: 460 mm x 230 mm
depth: 650 mm
Weight: 60 kg
Gas connection: connector 6 mm Swagelok
Materials:
Housing: SS 1.4301 (AISI 304)
Internal process cell: SS 1.4404 (AISI 316L)
Cell window: sapphire
Climatic conditions:
Ambient temperature: -30ºC to +60ºC
Ambient pressure: 800 – 1200 hPa
Ambient humidity: RH < 90%, non-condensing
Measurement conditions:
Precision: +/- 1% of the measured value or LOD and response time 30 sec
Accuracy: +/- 2% of the measured value or LOD and response time 30 sec
Conditioning of the sample: dry, free from oils and particles
Calibration: factory calibration using certified gas
Zero drift and span drift: irrelevant
Sample temperature: 0°C to 200°C (depends on application)
Safety:
Low Voltage Directive (LVD) 2014/35/EU PN-EN 61010 – 1:2011- Safety requirements for electrical equipment for measurement, control and laboratory use
PN-EN 60825 – 1:2014-11- Safety of laser products
EMC Directive 2014/30/EU EN 61326-1:2013-06 – Electrical equipment for measurement, control and laboratory use
RoHS Directive 2011/65/EU
EN IEC 60079-0:2018 – Explosive atmospheres – Part 0: Equipment – General requirements
EN 60079-2:2014 – Explosive atmospheres – Part 2: Equipment protection by pressurized enclosure “p”
EN 60079-26:2015 – Explosive atmospheres – Part 26: Equipment with Equipment Protection Level (EPL) Ga
EN 60079-28:2015 – Explosive atmospheres – Part 28: Protection of equipment and transmission systems using optical radiation
ATEX Directive 2014/34/EU  
Explosion protection (standard version):

  • ATEX II 3G [Ex op is IIC T6 Gc]
  • ATEX II 3D [Ex op is IIIC T85°C Dc]
Explosion protection – ATEX Zone 1/21 (optional version):

GasEye Extractive Ex1:

  • II 1/2G Ex op is pxb IIC T* Ga/Gb
  • II 1/2D Ex op is pxb IIIC T** Da/Db

GasEye Extractive Ex1 ET:

  • II 1/2G Ex db eb h ia ib op is pxb q IIC T* Ga/Gb
  • II 1/2D Ex h ia ib op is tb pxb q IIIC T** Da/Db

*/** temperature class depends on the medium temperature according to:

ID Medium temperature: Ambient conditions: Temperature class: Maximum surface temperature:
1 < 50°C -30°C to 50°C T6 85°C
2 < 100°C -30°C to 60°C T5 100°C
3 < 135°C -30°C to 60°C T4 135°C
4 < 200°C -30°C to 60°C T3 200°C

Certificate No. KDB 20ATEX0056X EN
Certificate No. KDB 20ATEX0056X PL

The post GasEye Extractive appeared first on Thomson Environmental Systems.

]]> GasEye Cross Duct MG (Multi Gas) https://thomsongroup.com.au/product/gaseye-cross-duct-mg-multi-gas/ Tue, 18 Jun 2024 03:12:15 +0000 https://thomsongroup.com.au/?post_type=product&p=20179 GasEye Cross Duct MG (Multi Gas) is a high performance in-situ analyzer that provides analysis for 17 standard gas combinations and can be customised for specific combinations. GasEye Cross Duct MG utilizes tunable diode laser (TDL) absorption spectroscopy. The central unit sends a laser light through the process which is detected by the receiver unit […]

The post GasEye Cross Duct MG (Multi Gas) appeared first on Thomson Environmental Systems.

]]>
GasEye Cross Duct MG (Multi Gas) is a high performance in-situ analyzer that provides analysis for 17 standard gas combinations and can be customised for specific combinations. GasEye Cross Duct MG utilizes tunable diode laser (TDL) absorption spectroscopy. The central unit sends a laser light through the process which is detected by the receiver unit mounted on the opposite side of the process. When a gas of interest is present in this process, it will absorb the laser light. The optical power detected in the receiver unit will depend on the concentration of the gas, temperature, pressure, and optical pathlength according to Lambert’s Beer law. Thus in order to determine the gas concentration, the analyzer requires information regarding temperature, pressure, and optical pathlength. Temperature and pressure signals can be provided by analog inputs, via industrial communication protocols, or as manual values via Webserver or HMI.

In the GasEye Cross Duct analyzer, the laser wavelength is specifically chosen to match the fingerprint region of the particular gas of interest and is being continuously scanned over the absorption line(s). Since full spectral information is recovered with very high spectral resolution the analyzer remains immune to foreign gas broadening and is immune to cross-interferences from dust and any other gas constituents in the process. GasEye Cross Duct by design can operate in several wavelength regions from Near-Infrared to Mid-Infrared.

Applications
  • Combustion control (boilers)
  • Safety monitoring
  • Electrofilter Protection.
Industries
  • Power industry
  • Steel industry
  • Chemical industry.
Multi-Gas Combinations
  • CO+O2
  • CO+CO2
  • CO+CH4
  • H2S+O2
  • HCHO+H2O
  • HCOOH+CO
  • HCL+H2O
  • NH3+H2O
  • NO+NH3
  • NO+O2
  • NO+NO2
  • CO+CH4+O2
  • CO+O2+H2O+CH4
  • C2H2+C2H4+C2H6
  • SO2+HCL+NH3+H2O
  • SO2+HCL+NO+H2O
  • SO2+HCL+CO+H2O
Features
  • Process temperature: 0 – 1350°C
  • Real time sensing: response time below 0.2 second
  • High selectivity: automatic compensation for interference effect from other constituents in the gas sample
  • High sensitivity: detection limits down to ppb range
  • In-situ monitoring: direct in the process, no sample preparation
  • Maintenance free: equipped with a self-calibrating feature, no field calibration necessary
  • Robustness: IP66 enclosure, suitable for outdoor and indoor installations and harsh environments
  • Insensitive to dust and smoke in the measured process: up to 50 g/m3
  • ATEX version available.
Operating principle

GasEye Extractive is a laser spectrometer that uses single line molecular absorption spectroscopy. A semiconductor laser emits a beam of infrared light which passes through the process and impinges the detector on the receiver side. When the target gas is present the light intensity changes and this can be used to determine the concentration of the measured specimen. The wavelength of the radiation emitted by the laser is chosen to match the specific absorption line wavelength of the gas. The laser continuously scans this single absorption line with a very high spectral resolution. The measurement is free of cross-interferences since the laser light is absorbed very selectively by only one specific line in the scanned spectral range.

INFLUENCES ON THE MEASUREMENT
Temperature

The influence of temperature on the measured absorption line is compensated by internal algorithms. The process gas temperature must be provided as a signal into the instrument. The temperature measurement is used to apply a correction of the temperature on the observed line strength. Temperature compensation is obligatory and without it the concentration output is erroneous.

Pressure

The influence of pressure on the measured absorption line is compensated by internal algorithms. The process gas pressure must be provided as a signal into the instrument. For known pressure values, the GasEye Cross Duct spectrometer adapts the line shape. Additionally, an external pressure signal can be fed to the analyzer to provide complete mathematical compensation of the pressure influence including the density effect (depending on a specific application and target gas).

Interferences

The GasEye Cross Duct can measure the desired gas components very selectively. It may happen that the absorption line of the measured gas is influenced by the presence of other gases. This influence is compensated by the full shape of the detected signal curve analysis and applying algorithms that correct the discrepancies accordingly.

MG (Multi Gauge)
The GasEye Cross Duct MG (Multi Gauge) analyzer consists of a pair of cross-duct sensors – a transmitter and a receiver unit as well as a central unit. The transmitter unit emits laser radiation directly through the process containing the constituents of interest. The receiver unit collects the radiation on the other side of the process duct. The central unit, located close to the transmitter unit (< 2 meters) contains analyzer electronics, MMI and I/O. The receiver unit is connected to the central unit by means of a hybrid loop cable (included) and the transmitter unit is connected to the central unit by one or two electrical cables (included).

 

Transmitter
Dimensions: width x height: 230 mm x 200 mm,
length: 350 mm
Weight: 15 kg
Equipment: 2 x laser sockets,
purging fittings
Receiver
Dimensions: width x height: 160 mm x 160 mm,
length: 330 mm
Weight: 13 kg
Equipment: 1 cable gland,
purging fittings
Central Unit
Dimensions: width x height: 330 mm x 230 mm,
length: 110 mm
Weight: 6 kg
Equipment: display with status indicators,
6 cable glands, Ethernet socket,
purging fittings
Protection standard
Degree of protection: In accordance with IP66
Process windows: Leak tested and certified in accordance with EN1779:1999 norm.

 



 

 

Safety

RoHS Directive 2011/65/EU  
Low Voltage Directive (LVD) 2014/35/EU PN-EN 60825-1:2014-11 – Safety of laser products – Part 1: Equipment classification and requirements
PN-EN 61010-1:2011 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements
Electromagnetic Compatibility Directive (EMC) 2014/30/UE Emission:
EN 55016-2-1:2014+A1:2017 – Measurements of conducted disturbances emission
EN 55016-2-3:2017+A1:2019 – Measurements of radiated disturbances emission
Immunity:
EN 61000-4-2:2009 – Electrostatic discharge immunity
EN 61000-4-3:2006 + A1:2008 + A2:2010 – Radiated, electromagnetic field immunity
EN 61000-4-4:2012 – Electrical fast transient / burst immunity
EN 61000-4-5:2014 + A1:2017 – Surge immunity
EN 61000-4-6:2014 – Immunity to conducted disturbances
EN 61000-4-29:2000 – Immunity to voltage dips, short interruptions and voltage variations
ATEX Directive 2014/34/EU EN IEC 60079-0:2018 – Explosive atmospheres – Part 0: Equipment – General requirements
EN 60079-2:2014 – Explosive atmospheres – Part 2: Equipment protection by pressurized enclosure “p”
EN 60079-11:2012 – Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “i”
EN 60079-26:2015 – Explosive atmospheres – Part 26: Equipment with Equipment Protection Level (EPL) Ga
EN 60079-28:2015 – Explosive atmospheres – Part 28: Protection of equipment and transmission systems using optical radiation
Explosion protection (standard version):

  • ATEX II 3G [Ex op is IIC T6 Gc]
  • ATEX II 3D [Ex op is IIIC T85°C Dc]
Explosion protection – ATEX Zone 1/21 (optional version):
GasEye Cross Duct Ex1:

  •  II 1/2G Ex pxb op is IIC T6 Ga/Gb
  •  II 1/2D Ex pxb op is IIIC T85°C Da/Db

GasEye Cross Duct Ex1 IS:

  •  II 1/2G Ex pxb ia op is IIC T6 Ga/Gb
  •  II 1/2D Ex pxb ia op is IIIC T85°C Da/Db

GasEye Cross Duct Ex1 ET and GasEye Cross Duct Ex1 ET IS:

  •  II 1/2G Ex db eb h ia ib op is pxb q IIC T4 Ga/Gb
  •  II 1/2G Ex h ia ib op is pxb q tb IIIC T135°C Da/Db

Certificate No. KDB 20ATEX0003X EN
Certificate No. KDB 20ATEX0003X PL

Explosion protection – IECEx Zone 2/22 (optional version):

  •  op is pzc IIC T6 Gc
  •  op is pzc IIIB T85°C Dc

Certificate No. IECEx KDB 19.0004X

The post GasEye Cross Duct MG (Multi Gas) appeared first on Thomson Environmental Systems.

]]>
smart/ECS Multi Gas Sensor https://thomsongroup.com.au/product/smart-ecs-gas-measurement/ Tue, 22 Feb 2022 04:47:38 +0000 https://thomsongroup.com.au/?post_type=product&p=19152 smart/ECS Multi Gas Sensor JES Tunnel Safety offer the Smart/ECS, an IoT-enabled gas sensor that can detect up to four gases: (CO, NO, NO2, SO2 – other gases on request). Features Smart IoT enabled gas sensor Electrochemical measurement of gas concentration with up to 4 gas sensor modules Pre-calibrated gas sensor modules for different gases and measuring […]

The post smart/ECS Multi Gas Sensor appeared first on Thomson Environmental Systems.

]]>
smart/ECS Multi Gas Sensor

JES Tunnel Safety offer the Smart/ECS, an IoT-enabled gas sensor that can detect up to four gases: (CO, NO, NO2, SO2 – other gases on request).

Features

  • Smart IoT enabled gas sensor
  • Electrochemical measurement of gas concentration with up to 4 gas sensor modules
  • Pre-calibrated gas sensor modules for different gases and measuring ranges, including CO, NO, NO2, SO2
  • Installation in-situ in the tunnel’s driving area or extractive with hose adapters
  • Stainless steel housing 1.4404 (AISI 316L)
  • Sensor protected against splashing of water and powerful water jets used for tunnel washing
  • IP rating IP69K
  • Optional LCD in housing cover
  • Integrated web server for visualisation, configuration, data logging, remote maintenance
  • Connection to tunnel control system by
    • MODBUS/TCP (Ethernet)
    • MODBUS RTU (RS-485)
    • Analogue and relay outputs (optional)
    • OPC UA (Ethernet)
  • Optional smart/HUB IoT operating and control unit with touch display

System Set-up

  • Smart IoT sensor for up to 4 gas sensor modules
  • Exchangeable, pre-calibrated gas sensor modules
  • Connection either to tunnel control system or optional oper-ating and control unit smart/HUB

Operation

Gas monitoring during normal operation is used to control the tunnel ventilation at normal operation. If and with how much power artificial ventilation by jet fans is operated depends on the measured visibility and gas concentration.

Electrochemical gas sensor cells induce currents proportional to the prevailing gas concentration. With these currents and the measured temperature, the gas sensor modules calculate the gas concentrations.

Advantages

  • Specifically designed for application in tunnels
  • Robust stainless steel housing for protection against corrosion and water jets
  • Permanent condition monitoring
  • Remote maintenance
  • Low maintenance requirements, stable, accurate
  • Pre-calibrated gas sensor modules for easy exchange
  • Flexible integration into tunnel control system
  • Ethernet port
  • Mounting height in accordance with Austrian RVS
  • Menu guided recalibration of gas sensor modules
  • Smart IoT solution from sensor over hub to asset management software.Download Specifications

The post smart/ECS Multi Gas Sensor appeared first on Thomson Environmental Systems.

]]>
TELEDYNE API 751H Portable Zero Air Generator (TAPI) https://thomsongroup.com.au/product/teledyne-api-751h-portable-zero-air-generator-tapi/ Fri, 05 Jul 2019 05:59:40 +0000 https://thomsongroup.com.au/?post_type=product&p=17787 The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes. The […]

The post TELEDYNE API 751H Portable Zero Air Generator (TAPI) appeared first on Thomson Environmental Systems.

]]>
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.

The 751H includes a dew point sensor, a small, powerful pump, scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3 plus high performance scrubbers to remove CO and Hydrocarbons. The regenerative heatless dryer removes water and produces output with a dew point of -20ºC (up to 10 SLPM flow rate).

The 751H features tank-less operation for real-time pressurised output without “pulsing.” A micro-controller cycles the regenerative dryer and pressurized drain and features a short cycle interval of 1 minute for high humidity applications.

Features

  • Rugged traveling case with wheels and retractable handle
  • Dew point indicator
  • Long life scrubbers for SO2, NO, NO2, O3, H2S, and NH3
  • High Performance CO/Hydrocarbon scrubber
  • Regenerative, heat-less dryer for maintenance-free water removal
  • Automatic water drain
  • Once/year maintenance interval
  • Two-year warranty.

DOWNLOAD Datasheet

The post TELEDYNE API 751H Portable Zero Air Generator (TAPI) appeared first on Thomson Environmental Systems.

]]>