Flue Gas Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-tag/flue-gas/ Tue, 03 Jun 2025 03:14:41 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Flue Gas Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-tag/flue-gas/ 32 32 Gas Sample Dilution Probe SP2000-H/DIL https://thomsongroup.com.au/product/gas-sample-dilution-probe-sp2000-h-dil/ Fri, 23 Jun 2023 05:35:39 +0000 https://thomsongroup.com.au/?post_type=product&p=20021 The electrically heated M&C dilution probe is used in processes where the measuring procedure or the handling of the process gas requires the dilution of the sample gas or the component(s) to be measured, e.g. for extremely toxic gases, for moisture or emission measurement in flue gases. Since the M&C dilution probe SP2000-H/DIL is based […]

The post Gas Sample Dilution Probe SP2000-H/DIL appeared first on Thomson Environmental Systems.

]]>
The electrically heated M&C dilution probe is used in processes where the measuring procedure or the handling of the process gas requires the dilution of the sample gas or the component(s) to be measured, e.g. for extremely toxic gases, for moisture or emission measurement in flue gases.

Since the M&C dilution probe SP2000-H/DIL is based on the well-proven M&C gas sample probe SP2000H, a variety of applications requiring special filter techniques, materials, etc. can be handled without any problems with this dilution probe.

Gas sample dilution probe type SP2000‑H/DIL features:

  • external ceramic filter type S‑2K150
  • filter porosity: 2 µm
  • electrically heated external filter from 0 to 180 °C, adjustable by an integrated thermostat
  • high‑temperature limiter with reset key responding at +30 °C above Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset,
  • incl. weather protection shield with insulation
  • power: 230 V/50 Hz, 800 W
  • mounting flange: DN 65 PN 6B with G 3/4″ f connection
  • sample gas OUT: 8‑mm‑tube
  • material: SS 316Ti, ceramic, Viton®
  • Dilution ratio to be indicated with the order

Gas Sample Dilution Probe SP2000-H/DIL brochure

 

The post Gas Sample Dilution Probe SP2000-H/DIL appeared first on Thomson Environmental Systems.

]]>
Portable Gas Sample Probe PSP4000-H https://thomsongroup.com.au/product/portable-gas-sample-probe-psp4000-h/ Thu, 04 May 2023 22:52:41 +0000 https://thomsongroup.com.au/?post_type=product&p=19977 Portable gas sample probe type PSP4000‑H with external ceramic filter type S‑2K, filter porosity: 2 µm, electrically heated external filter 100 to 180 °C adjustable by an integrated thermostat with indicator light (standard: 180 °C), 7‑pin plug with 4 m connection cable and mains plug, thermally insulated housing with carrying handle and chain incl. mounting […]

The post Portable Gas Sample Probe PSP4000-H appeared first on Thomson Environmental Systems.

]]>
Portable gas sample probe type PSP4000‑H with external ceramic filter type S‑2K, filter porosity: 2 µm, electrically heated external filter 100 to 180 °C adjustable by an integrated thermostat with indicator light (standard: 180 °C), 7‑pin plug with 4 m connection cable and mains plug, thermally insulated housing with carrying handle and chain incl. mounting clamp for connecting the heated sample line, gas inlet: G 3/8″ f, gas outlet: G 1/8″ NPT with tube connector 6 mm, power: 230 V/50 Hz, 200 W, material: SS 316Ti, ceramics, Viton®

Gas Sample Probe SP4000-H brochure

The post Portable Gas Sample Probe PSP4000-H appeared first on Thomson Environmental Systems.

]]>
Gas Sample Probe SP2000-H https://thomsongroup.com.au/product/gas-sample-probe-sp2000-h/ Thu, 04 May 2023 05:57:24 +0000 https://thomsongroup.com.au/?post_type=product&p=19972 Gas sample probe type SP2000‑H with external ceramic filter type S‑2K150, filter porosity: 2 µm, with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, high‑temperature limiter with reset key responding at +30 °C Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset, incl. weather protection shield […]

The post Gas Sample Probe SP2000-H appeared first on Thomson Environmental Systems.

]]>
Gas sample probe type SP2000‑H with external ceramic filter type S‑2K150, filter porosity: 2 µm, with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, high‑temperature limiter with reset key responding at +30 °C Tset and low‑temperature alarm with potential‑free status‑alarm contact at ‑30 °C below Tset, incl. weather protection shield with insulation, power: 230 V/50 Hz, 800 W, mounting flange: DN 65 PN 6B with G 3/4″ f connection, sample gas OUT: 1/4″ NPT f, material: SS 316Ti, ceramic, Viton®

Gas Sample Probe Series SP®Versions SP2000, SP2000-H, SP2300-H, SP2400-H range brochure

The post Gas Sample Probe SP2000-H appeared first on Thomson Environmental Systems.

]]>
Enotec CEMTEC https://thomsongroup.com.au/product/enotec-cemtec/ Sat, 03 Nov 2018 17:40:50 +0000 https://thomsongroup.com.au/?post_type=product&p=17193 CEMTEC® has self-cleaning properties and unparalleled mechanical strength for continuous measurement for pyro process optimization in cement plants. Information The CEMTEC® gas sampling probe system was developed for continuous analysis of flue gas in cement plant rotary kiln inlets and other extremely dusty, high temperature processes such as in lime plants with the goal of increasing product quality with […]

The post Enotec CEMTEC appeared first on Thomson Environmental Systems.

]]>
CEMTEC® has self-cleaning properties and unparalleled mechanical strength for continuous measurement for pyro process optimization in cement plants.

Information

The CEMTEC® gas sampling probe system was developed for continuous analysis of flue gas in cement plant rotary kiln inlets and other extremely dusty, high temperature processes such as in lime plants with the goal of increasing product quality with reduced fuel usage while simultaneously reducing harmful emissions.

With the increasing usage of alternative fuels in rotary kilns and large combustion chambers, on-site gas analysis has become more important.
In addition, stringent emission targets worldwide are driving the need for quality continuous process measurement and SNCR control for NOx reduction.

Process temperatures up to 1400°C, dust concentrations of up to 2000 g/, high mechanical stress and ambient temperatures up to 50°C make extreme demands on any equipment. CEMTEC® unique features provide an optimal solution for uninterrupted measurement under challenging conditions as found in kiln inlet chambers.

The CEMTEC® is self-cleaning which enables 95% availability of measurement during operation. In addition to the InSitu sensors for oxygen and COeanalysis, extractive analyzers are supplied with dust free flue gas for measurement of e.g. SO2, NOx or CO2.

Due to its mechanical cleaning, continuous extraction and analysis of process gas is possible over a long period of time: The plunger at the gas inlet removes any deposits or blockages, keeping the gas inlet free. The patented swivel drive continuously rotates the probe in programmable intervals and prevents deformation of the probe tube and enables probe retraction at any time.

Applications

  • Cement plants
  • Lime plants
  • High temperature, high dust applications

Features

  • 95 % availability of measurement
  • Swivel drive
  • Automated self cleaning
  • Automatic emergency retraction
  • Optional InSitu O2 / COe analysis