Tekran Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-brands/tekran/ Thu, 05 Jun 2025 02:35:13 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Tekran Archives - Thomson Environmental Systems https://thomsongroup.com.au/product-brands/tekran/ 32 32 TEKRAN 2537X Automated Ambient Air Mercury Analyzer https://thomsongroup.com.au/product/tekran-2537x-automated-ambient-air-mercury-analyzer/ Wed, 26 Sep 2018 05:57:09 +0000 https://thomsongroup.com.au/?post_type=product&p=16640 The Tekran® 2537X performs continuous long-term, unattended analysis of gaseous elemental mercury with unmatched accuracy, sensitivity, and reliability. The Tekran® 2537X is easy to setup, use, and maintain and is known for its stable performance in rugged conditions – installed at both Polar Regions, on ocean research vessels and hundreds of locations in between. As […]

The post TEKRAN 2537X Automated Ambient Air Mercury Analyzer appeared first on Thomson Environmental Systems.

]]>
The Tekran® 2537X performs continuous long-term, unattended analysis of gaseous elemental mercury with unmatched accuracy, sensitivity, and reliability.

The Tekran® 2537X is easy to setup, use, and maintain and is known for its stable performance in rugged conditions – installed at both Polar Regions, on ocean research vessels and hundreds of locations in between. As a testament to the longevity of our products, the first Tekran® 2537X analyzers produced are still running strong and producing quality data with over 15 years of continuous operation.

While the Tekran® 2537X is typically tasked with continuous ambient air monitoring, other applications are easy to achieve. For example, by continuously measuring the inlet and outlet of a flux chamber, the exceptional sensitivity of the 2537X can be used to determine differential surface emission and deposition rates. The 2537X is most often used with the model 1130 and 1135 to continuously measure atmospheric mercury speciation. The 2537X has also been applied to study and monitor mercury control technology, dissolved gaseous mercury, surface flux by gradient techniques, indoor air, plume chemistry, free-tropospheric air and point sources impacts, to name but a few. In cases where higher air concentrations are expected, the Tekran® 2537X can be purchased in an alternate configuration to extend the upper range of the analyzer. This is useful for industrial monitoring and site remediation projects where mercury concentrations are expected to far exceed the typical ambient air concentrations.

Key Features:

  • Touch screen interface
  • Local data storage and file retrieval
  • Low detection limit < 0.1 ng/m3
  • Fully compliant with EN 15852 Method
  • Internal permeation source for automated calibrations
  • Dual channel gold trapping for uninterrupted sampling
  • Network enabled with remote operation and control
  • Improved maintenance serviceability
  • Rugged platform with proven accuracy and stability.

Download Specifications

The post TEKRAN 2537X Automated Ambient Air Mercury Analyzer appeared first on Thomson Environmental Systems.

]]>
TEKRAN 1130 – Oxidised Mercury Speciation Module https://thomsongroup.com.au/product/tekran-1130-oxidised-mercury-speciation/ Wed, 26 Sep 2018 05:51:12 +0000 https://thomsongroup.com.au/?post_type=product&p=16637 The Tekran® Model 1130 Oxidized Mercury Speciation Unit expands the Model 2537 Mercury Vapor Analyzer capabilities to simultaneously monitor elemental and gaseous oxidized mercury (GOM, aka RGM) species in ambient air. The patented Model 1130 is the only system in the world capable of automated mercury speciation determinations in air. The Model 1130 is an invaluable […]

The post TEKRAN 1130 – Oxidised Mercury Speciation Module appeared first on Thomson Environmental Systems.

]]>
The Tekran® Model 1130 Oxidized Mercury Speciation Unit expands the Model 2537 Mercury Vapor Analyzer capabilities to simultaneously monitor elemental and gaseous oxidized mercury (GOM, aka RGM) species in ambient air. The patented Model 1130 is the only system in the world capable of automated mercury speciation determinations in air. The Model 1130 is an invaluable tool for research and monitoring programs and is well known for ruggedness, reliability, and performance in extreme environments. Extended instrument status and performance is monitored using Tekran® DataCom software to provide the operator with continuous quality assurance results.

Measurement of GOM with the Tekran® Model 1130 is the important link connecting deposition of air mercury to sensitive aquatic ecosystems. Emissions of GOM from point sources, in-situ production and transport can result in locally enhanced mercury deposition. Thus air speciation of mercury is of particular interest close to industrial sources. Over 100 peer-reviewed articles have been published featuring data generated by the Tekran® Model 1130 at field sites throughout the world. The Tekran® 2537-1130-1135 Atmospheric Mercury Speciation System has been chosen by networks around the world, including the, Canadian-CAPMoN, NADP AMNet, EU EMEP, Korea-NIER, Chinese Academy of Sciences and others around the world.

The majority of atmospheric mercury is present in elemental form, but differentiation is important due to the greater local impact of reactive (ionic) forms. The Model 1130 provides a supplemental pump system to minimise sample collection periods, and produce mercury-free air for use during analytical cycles.

Key Features:

  • Integrates seamlessly with the Tekran® 2537 Analyzer
  • Separate controller allows sensitive components to be indoors
  • Adsorbing surface is regenerated with each desorption cycle
  • Data logging option captures flows and temperatures.

Download Specifications

The post TEKRAN 1130 – Oxidised Mercury Speciation Module appeared first on Thomson Environmental Systems.

]]>
TEKRAN 1135 – Particulate Bound Mercury https://thomsongroup.com.au/product/tekran-1135-particulate-bound-mercury/ Wed, 26 Sep 2018 05:48:10 +0000 https://thomsongroup.com.au/?post_type=product&p=16634 The Tekran® Model 1135 Particulate Mercury Module connects seamlessly to the top of the Model 1130 to continuously monitor ambient air particulate bound mercury (HgP), gaseous oxidized mercury (GOM) and gaseous elemental mercury (GEM). The complete Tekran® 2537-1130-1135 Atmospheric Mercury Speciation System provides fully automated, unattended operation to determine all three mercury species concurrently. It […]

The post TEKRAN 1135 – Particulate Bound Mercury appeared first on Thomson Environmental Systems.

]]>
The Tekran® Model 1135 Particulate Mercury Module connects seamlessly to the top of the Model 1130 to continuously monitor ambient air particulate bound mercury (HgP), gaseous oxidized mercury (GOM) and gaseous elemental mercury (GEM).

The complete Tekran® 2537-1130-1135 Atmospheric Mercury Speciation System provides fully automated, unattended operation to determine all three mercury species concurrently. It is the only system available which has this advanced capability to routinely measure part per quadrillion mercury speciation in ambient air.

Measurement of Hgp with the Tekran® Model 1135 is the important link connecting deposition of air mercury to sensitive aquatic ecosystems. Emissions of Hgp from point sources, in-situ production and transport can result in locally enhanced mercury deposition. Thus, air speciation of mercury is of particular interest close to industrial sources.

Networks around the world have chosen the Tekran® 1135 for mercury speciation monitoring in air.

Conventional particulate sampling is not successful at separating mercury species since GOM has a high affinity for surfaces and sticks to filter media, biasing results. The Tekran® 1130 – 1135 Modules solve this problem by selectively capturing the GOM fraction from the sampled air stream prior to the Model 1135 particulate mercury filter element. Analysis occurs by heating and pyrolysis to release the HgP as GEM for detection and thermally decomposing the particulate matter. Enhanced instrument status and performance is monitored using Tekran® DataCom software, providing the operator with continuous quality assurance results.

Features:

  • Connects directly on top of 1130 – no additional mounting is required
  • Particulate filter is regenerated with each desorption cycle
  • Data logging option captures flows and temperatures

Download Specifications

The post TEKRAN 1135 – Particulate Bound Mercury appeared first on Thomson Environmental Systems.

]]>
TEKRAN 2600 Automated Total Mercury Analyser https://thomsongroup.com.au/product/tekran-2600-automated-total-mercury-analyser/ Wed, 26 Sep 2018 05:44:16 +0000 https://thomsongroup.com.au/?post_type=product&p=16631 The Tekran® Series 2600 system allows the analysis of ultra-trace levels of total mercury in laboratory prepared environmental samples (water, biota, soil, sediments, gas cartridges, effluents and more). It offers unparalleled sensitivity and flexibility for those who require truly sensitive total mercury analysis. The Series 2600 is capable of providing a fully automated implementation of […]

The post TEKRAN 2600 Automated Total Mercury Analyser appeared first on Thomson Environmental Systems.

]]>
The Tekran® Series 2600 system allows the analysis of ultra-trace levels of total mercury in laboratory prepared environmental samples (water, biota, soil, sediments, gas cartridges, effluents and more).

It offers unparalleled sensitivity and flexibility for those who require truly sensitive total mercury analysis.

The Series 2600 is capable of providing a fully automated implementation of EPA Method 1631. This method is capable of measuring waters and digested solids with detection limits over 10X lower than required.

Features:

Capable of multiple method configurations:

  • Dual stage gold preconcentration (EPA Method 1631)
  • Direct measurement without preconcentration (EPA Method 245.7)
  • Air sample analysis on gold traps (EPA Compendium Method IO-5)
  • Natural gas analysis on gold traps (ASTM D-6350, ISO 6978)

Comprehensive Tek-MDS-2 Software Package developed in-house and fully supported.

Download Specifications

The post TEKRAN 2600 Automated Total Mercury Analyser appeared first on Thomson Environmental Systems.

]]>
TEKRAN 2700 Methyl Mercury Analysis System https://thomsongroup.com.au/product/tekran-2700-methyl-mercury-analysis-system/ Wed, 26 Sep 2018 05:40:05 +0000 https://thomsongroup.com.au/?post_type=product&p=16627 The Tekran® 2700 Methyl Mercury Auto-Analysis System gives analytical laboratories and researchers automated alternatives to time-consuming and complex manual EPA method 1630 techniques. The Model 2700 offers a fully integrated, compact unit based on atomic fluorescence detection and operated via reliable, intuitive software. The system is pre-programmed to run EPA Method 1630, However, the Model […]

The post TEKRAN 2700 Methyl Mercury Analysis System appeared first on Thomson Environmental Systems.

]]>
The Tekran® 2700 Methyl Mercury Auto-Analysis System gives analytical laboratories and researchers automated alternatives to time-consuming and complex manual EPA method 1630 techniques.

The Model 2700 offers a fully integrated, compact unit based on atomic fluorescence detection and operated via reliable, intuitive software.

The system is pre-programmed to run EPA Method 1630, However, the Model 2700 offers complete method customization including: 1) GC column temperature ramping, 2) Programmable analysis cycle settings, 3) High temperature purge cycles and 4) Choice of trap and GC column. The 2700 will also seamlessly interface with ICP-MS or other analytical instruments.

The Model 2700 enclosure is specially designed for easy access to all serviceable components (e.g. GC column, detector, Tenax/Carbo trap). The Model 2700 includes integrated trouble shooting features such as pre-programmed leak check event cycles and software-based step by step detector maintenance guides. The superior design and features make the Model 2700’s the analyzer of choice for your methyl mercury laboratory.

Features:

  • Sample analysis cycle < 7 minutes per sample
  • Highly sensitive, ultra-stable CVAFS Hg detector
  • MDL of 0.002 ng/L
  • Intuitive, reliable TekMDS 2.7 software (based on the 2600 Series)
  • IR trap heating and active cooling
  • Liquid detector shuts down system in case of sample foaming or malfunction
  • Small footprint (51cm X 35cm X 52cm, L:W:H)

Download Specifications

The post TEKRAN 2700 Methyl Mercury Analysis System appeared first on Thomson Environmental Systems.

]]>