Products - Thomson Environmental Systems https://thomsongroup.com.au/products/ Thu, 26 Jun 2025 04:26:29 +0000 en-AU hourly 1 https://wordpress.org/?v=6.9 https://thomsongroup.com.au/wp-content/uploads/2022/03/cropped-TES_favicon-32x32.png Products - Thomson Environmental Systems https://thomsongroup.com.au/products/ 32 32 Model 3110​​ / 3110P / 3110XL https://thomsongroup.com.au/product/model-3110-3110p-3110xl/ Thu, 26 Jun 2025 04:18:51 +0000 https://thomsongroup.com.au/?post_type=product&p=21118 The Model 3110 represents the new generation of portable trace and percent oxygen analysis capabilities. It combines a rugged, portable analyzer with the high reliability of trace and percent level sensors. This ensures highly accurate ppm/ percent oxygen readings in a variety of background gases (including hydrocarbons). In addition, the microprocessor-based electronics provide accurate, high […]

The post Model 3110​​ / 3110P / 3110XL appeared first on Thomson Environmental Systems.

]]>
The Model 3110 represents the new generation of portable trace and percent oxygen analysis capabilities. It combines a rugged, portable analyzer with the high reliability of trace and percent level sensors. This ensures highly accurate ppm/ percent oxygen readings in a variety of background gases (including hydrocarbons). In addition, the microprocessor-based electronics provide accurate, high resolution readings and easy-to-use features.​

3110: 0-10ppm to 10,000ppm with Micro-Fuel Cell

3110P: 0-1% to 0-25% with Micro-Fuel Cell

3110XL: 0-2ppm to 10,000ppm with Micro-Fuel Cell

Features

    • Ranges: 0-10 ppm to 0-10,000 ppm with 0-25% over-range
    • Analyzer is intrinsically safe, FM-approved for Class I Div 1 Groups D and ATEX-approved for Zone 0 (ia) IIC*
    • Sensor: Micro-fuel Cell Class B-2C
    • Calibration: In ambient air or with a certified span gas
    • System power requirements: AC power for battery recharge circuit of two current limited rechargeable NiCad batteries,
    • 0-1V analog output​​
    • Digital meter readout
    • Steel quick-disconnect fittings with nylon cell block; mating set (3) of male fittings (vent, sample, calibration); calibration hose
    • Carrying case (P/N: E834) – black, durable plastic, foam interior, or (P/N: E836) larger case for a unit with a sample system​

    *third-party approved only for O2 levels below 20.9%

Applications

  • Air separation and liquefaction
  • Pure gaseous hydrocarbon stream monitoring
  • Semiconductor manufacturing
  • Protective atmosphere blanketing of primary liquid feedstocks​ and flammable liquids
  • Process analysis of gaseous monomers – vinyl chloride, propylene, butadiene, isoprene or ethylene
  • Gas purity certification
  • Glove box or pipeline leak detection
  • Natural gas treatment and transmission
  • Catalyst protection
  • Inert gas welding of exotic metals
  • Wave and re-flow soldering
  • Heat treating and bright annealing
  • Nuclear fuel processing and isotope separation
  • Analysis of chemical reactions
  • Head space gas analysis
  • Crystal growth
  • Plastics manufacturing

Download Brochure

The post Model 3110​​ / 3110P / 3110XL appeared first on Thomson Environmental Systems.

]]>
Model 7500za-7600za https://thomsongroup.com.au/product/model-7500za-7600za/ Thu, 26 Jun 2025 03:48:55 +0000 https://thomsongroup.com.au/?post_type=product&p=21114 The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design. Features 4-digit indication, LCD with CFL Backlight Follow & […]

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
The 7500ZA and 7600ZA Infrared (IR) Analyzers are capable of detecting IR absorbing components on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, multi-component analysis, and cost-effective design.

Features

  • 4-digit indication, LCD with CFL Backlight
  • Follow & Hold output signal control (during calibration)
  • Remote range change control
  • 85-264 VAC 50/60 Hz power
  • Simultaneous measurement of up to multiple components, one or two ranges each
  • In-depth, valuable analyzer functions attainable from the front panel user interface buttons
  • Range ID signals
  • Instrument or calibration error contact outputs
  • 19” rack configuration with optional slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine-tune analyzer performance.

Applications

  • Emission Gas Analysis
  • Food and Beverage CO2 Analysis
  • Industrial Bulk Gas Analysis.

Download Brochure

The post Model 7500za-7600za appeared first on Thomson Environmental Systems.

]]>
TECORA Isokinetic G8 https://thomsongroup.com.au/product/tecora-isoskinetic-g8/ Fri, 13 Jun 2025 00:15:07 +0000 https://thomsongroup.com.au/?post_type=product&p=21074 After more than 40 years of experience with automatic isokinetic sampling systems the 3rd generation isokinetic sampler, ISOKINETIC G8, is the most advanced sampler in the market, updated to all EN and EPA standards as well as fully compliant to the metrological chain requirements mentioned in the standard ISO17025. With new digital architecture and improved […]

The post TECORA Isokinetic G8 appeared first on Thomson Environmental Systems.

]]>
After more than 40 years of experience with automatic isokinetic sampling systems the 3rd generation isokinetic sampler, ISOKINETIC G8, is the most advanced sampler in the market, updated to all EN and EPA standards as well as fully compliant to the metrological chain requirements mentioned in the standard ISO17025.

With new digital architecture and improved automation, the G8 improves on the very stable and easy to use G4 platform and user interface.

Warning and alarm messages are sent to your phone via G8 app, so you have total control any time, anywhere!

New internal components provide significant weight and footprint reductions for better handling/transportability which improves user productivity in sampling platforms with limited space.

Features

  • Connection with online analyzer to acquire CO2 and O2 data for an accurate and real time gas density calculation (optional). Also other pollutants can be archived in a dedicated report
  • Advanced digital high resolution differential pressure sensors with near zero drift. High temperature stability over the sampling period
  • Fixed point stack gas speed measure as required from ISO16911-1
  • Automatic unattended sensor verification
  • Wide resistive touch screen. any type of touching material can manage it (gloves, pen, etc). All the informations are available in a clear high res view
  • Connection with swirl angle meter to verify the flow as required from ISO16911-1 (optional)
  • Background diagnostic test procedure to ensure total efficiency during sampling
  • USB interface to download data
  • Total isokinetic control within the standard limits with very fast response and high flow stability even in the most unstable stack gas speed conditions
  • Volume measurement with dry gas meter
  • Sampling flow measurement with venturi flow meter
  • In-stack temperature and velocity measurement
  • Wide duct library to archive all site data
  • Data logger function with saving data on internal memory or external USB key (supplied with the instrument)
  • Very high MTBF which results in low maintenance and low spares cost
  • All sensors can be calibrated as required from ISO17025
  • Auto check at starting
  • Leak test in line during sampling using an O2 sensor
  • Log measurements and alarms
  • Automatic re-start in case of flue gas velocity alarm.

Download Brochure

The post TECORA Isokinetic G8 appeared first on Thomson Environmental Systems.

]]>
MesaLabs Flexcal Series https://thomsongroup.com.au/product/mesalabs-flexcal-series/ Thu, 12 Jun 2025 01:17:57 +0000 https://thomsongroup.com.au/?post_type=product&p=21047 Highly Accurate Portable Gas Flow Calibrator Mesa Labs’ newest standardized and volumetric primary flow standard offers easy-to-navigate calibrations with unparalleled flow ranges, accuracy and portability. The FlexCal features: USB connectivity Flow ranges from 5 ccm to 50 LPM Quick start operation Graphical LCD display User-selectable flow units and time interval CE/RoHS Compliant The FlexCal offers […]

The post MesaLabs Flexcal Series appeared first on Thomson Environmental Systems.

]]>
Highly Accurate Portable Gas Flow Calibrator

Mesa Labs’ newest standardized and volumetric primary flow standard offers easy-to-navigate calibrations with unparalleled flow ranges, accuracy and portability. The FlexCal features:

  • USB connectivity
  • Flow ranges from 5 ccm to 50 LPM
  • Quick start operation
  • Graphical LCD display
  • User-selectable flow units and time interval
  • CE/RoHS Compliant

The FlexCal offers flow ranges up to 50 LPM with a standardized accuracy of 0.5%, but is small, easy to carry and ready for even the most demanding of applications. When you use Mesa Labs’ FlexCal, you are guaranteed high accuracy with high confidence without the use of soap bubbles, timers, or heavy provers.

Download Data Sheet

Technical Specifications

  FlexCal-H FlexCal-M FlexCal-L
Flow Ranges 0.5 – 50 LPM 50 ccm – 5 LPM 5 – 500 ccm
Accuracy 0.5% of reading
User selectable
measurement units
Volumetric mL/min, L/min, cc/min, cf/min
Standardised smL/min, sL/min, scc/min, scf/min
Temperature oC    oF
Pressure mmHg, PSI, kPa
Temperature and Pressure sensor Yes, in flow stream
Dimensions (HxWxD) 6.7 x 6.25 x 2.9 in / 170 x 159 x 73.5 mm
Weight 3 lb / 1.36 kg

The post MesaLabs Flexcal Series appeared first on Thomson Environmental Systems.

]]>
SHP1 Pyrheliometer https://thomsongroup.com.au/product/shp1-pyrheliometer/ Wed, 11 Jun 2025 05:46:15 +0000 https://thomsongroup.com.au/?post_type=product&p=21040 The combination of the CHP1 sensor technology with smart interface advantages makes the SHP1 even better, and with faster response. The smart interface not only provides versatile outputs, the integrated temperature sensor and digital polynomial functions also provide individual correction for the temperature sensitivity of the detector from -40 °C to +80 °C. The standardised […]

The post SHP1 Pyrheliometer appeared first on Thomson Environmental Systems.

]]>
The combination of the CHP1 sensor technology with smart interface advantages makes the SHP1 even better, and with faster response.

The smart interface not only provides versatile outputs, the integrated temperature sensor and digital polynomial functions also provide individual correction for the temperature sensitivity of the detector from -40 °C to +80 °C. The standardised output makes it easy to interchange instruments for recalibration.

SHP1 pyrheliometers have extremely low power consumption so that internal heating does not affect the detector performance. They operate from a wide range of supply voltages, making them ideal for power-critical applications, and the power input is protected against reversed polarity.

Two versions are available, SHP1-V has an analogue output of 0-1 V, SHP1-A is 4-20 mA. Both have a 2-wire RS-485 serial interface with Modbus® RTU protocol that provides a range of instrument status and configuration information, with user-selectable options.

The analogue outputs allow easy connection to virtually any data logger without the need for sensitive mV inputs. Modbus® interfaces directly to PLC and SCADA systems, industrial networks and controllers. A recalibrated instrument keeps the same analogue and digital measurement ranges, saving time by eliminating re-scaling of data collection equipment.

Kipp & Zonen SmartExplorer Windows™ software for instrument configuration, data display and data logging is available at no charge.

Download Data Sheet

Download Brochure

The post SHP1 Pyrheliometer appeared first on Thomson Environmental Systems.

]]>
SUV5 Total UV Radiometer https://thomsongroup.com.au/product/suv5-total-uv-radiometer/ Wed, 11 Jun 2025 05:40:32 +0000 https://thomsongroup.com.au/?post_type=product&p=21038 SUV5 is a Smart version of the CUV5 with digital signal processing. The accurate polynomial temperature correction and linearization make it ideal for monitoring high intensity UV lamps used in environmental test chambers.  Specific parts of the UV spectrum such as UVA, UVB or UVE / UV Index cannot be derived from the SUV5 measurements. […]

The post SUV5 Total UV Radiometer appeared first on Thomson Environmental Systems.

]]>
SUV5 is a Smart version of the CUV5 with digital signal processing. The accurate polynomial temperature correction and linearization make it ideal for monitoring high intensity UV lamps used in environmental test chambers. 

Specific parts of the UV spectrum such as UVA, UVB or UVE / UV Index cannot be derived from the SUV5 measurements. For measurement of these individual parameters our specific SUV models are required. 

SUV5 has a RS-485 interface with Modbus® RTU communication protocol and an amplified analog signal output. It can operate from 5 to 30 VDC and takes little power. The calibrated sensitivity is stored in the SUV memory so that the digital data is directly in W/m2 and the analog output range is standardized.  SUV’s can be interchanged and no changes have to be made in the data logger or data acquisition system after recalibration. 

Use our free SmartExplorer Windows™ software for display of data , data logging, to a PC and for changing Modbus® address and communication settings. 

SUV5 is compatible with the same accessories as our SMP range of pyranometers.

Download Data Sheet

The post SUV5 Total UV Radiometer appeared first on Thomson Environmental Systems.

]]>
CNR4 Net Radiometer https://thomsongroup.com.au/product/cnr4-net-radiometer/ Wed, 11 Jun 2025 05:33:04 +0000 https://thomsongroup.com.au/?post_type=product&p=21033 The CNR4 net radiometer measures the energy balance between incoming short-wave and long-wave Far Infrared (FIR) radiation versus surface-reflected short-wave and outgoing long-wave radiation. The CNR4 net radiometer consists of a pyranometer pair, one facing upward, the other facing downward, and a pyrgeometer pair in a similar configuration. The pyranometer pair measures the short-wave radiation. […]

The post CNR4 Net Radiometer appeared first on Thomson Environmental Systems.

]]>
The CNR4 net radiometer measures the energy balance between incoming short-wave and long-wave Far Infrared (FIR) radiation versus surface-reflected short-wave and outgoing long-wave radiation.

The CNR4 net radiometer consists of a pyranometer pair, one facing upward, the other facing downward, and a pyrgeometer pair in a similar configuration. The pyranometer pair measures the short-wave radiation. And the pyrgeometer pair measures long-wave radiation. The upper long-wave detector of CNR4 has a meniscus dome. This ensures that water droplets role off easily and improves the field of view to nearly 180°, compared with a 150° for a flat window. All 4 sensors are integrated directly into the instrument body, instead of separate modules mounted onto the housing. But are each calibrated individually for optimal accuracy.

Two temperature sensors, a Pt-100 and Thermistor, are integrated for compatibility with every data logger. The temperature sensor is used to provide information to correct the infrared readings for the temperature of the instrument housing. Care has been taken to place the long-wave sensors close to each other and close to the temperature sensors. This assures that the temperatures of the measurement surfaces are the same and accurately known. Which improves the quality of the long-wave measurements.

The design is very light in weight and has an integrated sun shield that reduces thermal effects on both long-wave and short-wave measurements. The cables are yellow with waterproof connectors as used with all our new radiometers. The mounting rod can be unscrewed for transport.

An optional CNF4 ventilation unit with heater is designed as an extension of the sunshield and can be fitted new to the CNR4 or retro-fitted later. This unit is compact and provides efficient air-flow over the domes and windows to minimize the formation of dew and reduce the frequency of cleaning. The integrated heater can be used to melt frost.

Download Data Sheet

The post CNR4 Net Radiometer appeared first on Thomson Environmental Systems.

]]>
DustIQ Soiling Monitoring System https://thomsongroup.com.au/product/dustiq-soiling-monitoring-system/ Wed, 11 Jun 2025 05:21:47 +0000 https://thomsongroup.com.au/?post_type=product&p=21027 DustIQ monitors the loss of light transmission caused by dust, sand, pollen, or any other particles on PV panels using Kipp & Zonen’s new and innovative Optical Soiling Measurement (OSM) technology. The DustIQ has no moving parts and it does not need sunlight to operate. Rather, it uses an internal light source to measures scattered […]

The post DustIQ Soiling Monitoring System appeared first on Thomson Environmental Systems.

]]>
DustIQ monitors the loss of light transmission caused by dust, sand, pollen, or any other particles on PV panels using Kipp & Zonen’s new and innovative Optical Soiling Measurement (OSM) technology. The DustIQ has no moving parts and it does not need sunlight to operate. Rather, it uses an internal light source to measures scattered and reflected light that is directly proportional to soiling accumulation on the surface of the DustIQ.

The DustIQ is unique because it does not require routine cleaning and mechanical maintenance, it is easily mounted directly in between framed PV modules on fixed and tracked sites, and is cleaned only when the modules are cleaned.

Module cleaning is most economically viable when the revenue losses and performance penalties caused by soiling exceed the operational costs of monitoring and cleaning. DustIQ provides the information for solar energy plant management systems so that you can decide exactly when and where to clean. The cost-effective price of the DustIQ makes it feasible to install a network of DustIQ units to monitor the variation in soiling over across an entire PV plant.

Download Data Sheet

The post DustIQ Soiling Monitoring System appeared first on Thomson Environmental Systems.

]]>
SOLYS2 Sun Tracker https://thomsongroup.com.au/product/solys2-sun-tracker/ Wed, 11 Jun 2025 04:41:21 +0000 https://thomsongroup.com.au/?post_type=product&p=21023 SOLYS2 is the most widely used sun tracker around the world in solar energy and meteorological applications. It has Baseline Surface Radiation Network (BSRN) levels of performance and reliability. Installation and operation of the SOLYS2 is much easier than many other sun trackers on the market. With the optional top mounting plate and shading assembly […]

The post SOLYS2 Sun Tracker appeared first on Thomson Environmental Systems.

]]>
SOLYS2 is the most widely used sun tracker around the world in solar energy and meteorological applications. It has Baseline Surface Radiation Network (BSRN) levels of performance and reliability. Installation and operation of the SOLYS2 is much easier than many other sun trackers on the market.

With the optional top mounting plate and shading assembly SOLYS2 can be configured as a complete solar monitoring station with up to three ventilated Kipp & Zonen radiometers. A large range of mounting kits is available for direct solar radiation instruments.

An advance over conventional sun trackers is the integrated GPS receiver to automatically configure location and time data upon installation. SOLYS2 does not require a computer and software for setup. Leveling is easily checked using the integrated bubble level on top.

The rugged and distinctive cast aluminum housing has an integrated tripod stand with leveling feet, azimuth adjustment and provision for tie-down bolts. A side plate with zenith adjustment and mountings for a Kipp & Zonen CHP1 pyrheliometer is included.

SOLYS2 does not suffer from internal clock drift because the time is regularly updated by the GPS receiver. If the tracker is correctly leveled and aligned, and mounted on a solid and stable support, it will continue to point accurately. An optional sun sensor is available for active tracking, to correct for motion in a support affected by changing environmental conditions.

SOLYS2 can operate from AC or 24 VDC power, both inputs are available as standard. The operating temperature range from – 20 °C to + 50 °C on DC power can be extended to -40 °C on AC power using the standard internal heater.

SOLYS2 brings to the sun tracker market distinctive design, innovative features, performance, quality and unprecedented ease of use – all at a surprisingly affordable price.

The design of the SOLYS2 sun tracker is based on Kipp & Zonen open source software.

Download Data Sheet

The post SOLYS2 Sun Tracker appeared first on Thomson Environmental Systems.

]]>
SOLYS Gear Drive Sun Tracker https://thomsongroup.com.au/product/solys-gear-drive-sun-tracker/ Wed, 11 Jun 2025 04:12:45 +0000 https://thomsongroup.com.au/?post_type=product&p=21015 SOLYS Gear Drive is a high end sun tracker for all weather conditions and locations. It builds on the features of the SOLYS 2 and has enhanced capabilities that make it suitable for use with heavy loads and in the harshest climates. It has the power to point accurately at the sun in very high […]

The post SOLYS Gear Drive Sun Tracker appeared first on Thomson Environmental Systems.

]]>
SOLYS Gear Drive is a high end sun tracker for all weather conditions and locations. It builds on the features of the SOLYS 2 and has enhanced capabilities that make it suitable for use with heavy loads and in the harshest climates. It has the power to point accurately at the sun in very high winds, and to break the ice that can build up overnight when the tracker is ‘sleeping’.

High payload for multiple and / or heavy instruments

The high precision gear drive system requires no regular maintenance and is much more powerful than the belt drive system of the SOLYS2. The maximum payload is increased to 80 kg and the torque is raised to 60 Nm, allowing SOLYS Gear Drive to carry multiple and/or heavy instruments and other loads. The integrated GPS receiver automatically configures location and very accurate time information upon installation.

Smart software for real-time status information

The included user interface software allows remote monitoring and logging of the tracker status, sun zenith and azimuth angles, GPS time and date and more. The software can also be used to set the communication parameters such as fixed or manual IP address and baud rate. The integrated Web Interface can be used to visualise (get and set) operational parameters, download history log files or upload new firmware when available.

What you need to build a solar monitoring station

To build your solar radiation measurement station the SOLYS Gear Drive is the base to hold an array of instruments to monitor solar and sky radiation. The shading assembly and other mounting accessories from the SOLYS2 can all be fitted. For operation in extremely cold regions an insulated cold weather cover is available that allows use in temperatures down to -50°C and with wind speeds up to 20m/s. For very hot climates a sun shield can be fitted, extending the upper temperature range to +60°C.

SOLYS Gear Drive has the mountings for pyrheliometer already fitted and includes the sun sensor for active tracking. However, it does not include a tripod stand. It can be used with the cast aluminum SOLYS Tripod Floor Stand but, for use in extreme conditions and with high loads, the Heavy Duty Tripod Floor Stand is recommended.

SOLYS Gear Drive has been tested and protected against the highest levels of ESD, EMC and surge disturbances that might be experienced.

The SOLYS Gear Drive sun tracker with high precision reduction gear combines the highest payload, the widest temperature range and most advanced communication with smart software for real-time status information.

Sun Tracker Comparison

OTT HydroMet offers three different models under its trusted brand Kipp & Zonen. The RaZON+, the SOLYS2, and the SOLYS Gear Drive. Read how to choose the right sun tracker model  on the OTT HydroMet Blog.

Download Data Sheet

The post SOLYS Gear Drive Sun Tracker appeared first on Thomson Environmental Systems.

]]>