{"id":17638,"date":"2019-01-09T12:02:45","date_gmt":"2019-01-09T01:02:45","guid":{"rendered":"https:\/\/thomsongroup.com.au\/?post_type=product&#038;p=17638"},"modified":"2025-05-22T12:32:20","modified_gmt":"2025-05-22T02:32:20","slug":"gasmet-flame-ionization-detector","status":"publish","type":"product","link":"https:\/\/thomsongroup.com.au\/product\/gasmet-flame-ionization-detector\/","title":{"rendered":"GASMET GFID Analyser"},"content":{"rendered":"<p>Gasmet Flame Ionization Detector (GFID) is designed for <strong>continuous total hydrocarbon (THC) measurements<\/strong>. GFID analyzer offers a T\u00dcV certified solution (QAL1) for measuring pollutants from hot, wet and corrosive gas streams.<\/p>\n<p>The measurement is based on fire ionization detection. The certified measuring ranges are from<strong> 0-15 to 0-500 mg\/m<sup>3<\/sup><\/strong>.<\/p>\n<p>The GFID analyzer is <strong>integrated to the Gasmet EN 15267 certified&nbsp;<\/strong> <a href=\"https:\/\/www.gasmet.com\/products\/category\/stationary-systems\/continuous-emissions-monitoring-system\/\" target=\"_blank\" rel=\"noopener\">Continuous Emission Monitoring System<\/a> CEMS ll <em>ef<\/em> and used in fully automatic mode.<\/p>\n<p>The Gasmet Flame Ionization Detector (GFID) is designed for continuous total hydrocarbon (THC) measurements. Gasmet Continuous Emission Monitoring System CEMS ll ef is equipped with GFID analyzer, offering a T\u00dcV certified solution (QAL1) for measuring pollutants from hot, wet and corrosive gas streams.<\/p>\n<h4>General parameters<\/h4>\n<ul>\n<li>Measuring principle: Fire ionization detection FID<\/li>\n<li>Response time: T90: &lt; 1.5s<\/li>\n<li>Operating temperature: 5 &#8211; 45\u00b0C<\/li>\n<li>Power supply: 115 or 230 V \/ 50 &#8211; 60 Hz<\/li>\n<li>Power consumption: 500 VA max.<\/li>\n<li>Sample flow rate: 2 l\/min<\/li>\n<li>Sample gas pressure: Ambient FID cell<\/li>\n<li>Heated block temperature: Up to 191\u00b0C<\/li>\n<li>Capillary block temperature: Heated up to 180\u00b0C<\/li>\n<li>Converter efficiency rate: &gt; 99 %<\/li>\n<\/ul>\n<h4>Measuring parameters<\/h4>\n<ul>\n<li>Ranges: 0-10\/100\/1,000\/10,000 ppm<\/li>\n<li>Accuracy: 1% of reading between 15% and 100% of full scale<\/li>\n<li>Noise: &lt; 0.5 % of full scale<\/li>\n<li>Span drift: &lt; 1 %\/24 h<\/li>\n<li>Zero drift: &lt; 1 %\/24 h<\/li>\n<li>Linearity: &lt; 1 % for a concentration between 10% and 100% of the full scale\u2019s range<\/li>\n<li>Lowest detection limit: 0.05 ppm on the 10ppm range<\/li>\n<\/ul>\n<h4>Utilities<\/h4>\n<ul>\n<li>Span gas: C3H8 or CH4<\/li>\n<li>Burner supply: H2\/He gas mixture (0.7 bar, 5 l\/h), Gas cylinder (180 bar, 50 l) lasts approximately 75 hours.<\/li>\n<li>Oxidizer: Instrument air<\/li>\n<\/ul>\n<h4>Additional features<\/h4>\n<ul>\n<li>Internal zero air catalyst converter<\/li>\n<li>Connected to Calcmet software through analog outputs<br \/>\nPlease refer to the CEMS II ef datasheet for system specific performance parameters<\/li>\n<li>Dimensions: 483 x 177 x 470 mm<\/li>\n<li>Weight: 22 kg<\/li>\n<\/ul>\n<p><a class=\"fasc-button fasc-size-xlarge fasc-type-glossy fasc-rounded-medium\" style=\"background-color: #1a4f7b; color: #ffffff;\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2025\/05\/Gasmet-GFID-Technical-Data-ID-8031.pdf\">Download Specifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gasmet Flame Ionization Detector (GFID) is designed for continuous total hydrocarbon (THC) measurements. GFID analyzer offers a T\u00dcV certified solution (QAL1) for measuring pollutants from hot, wet and corrosive gas streams. The measurement is based on fire ionization detection. The certified measuring ranges are from 0-15 to 0-500 mg\/m3. The GFID analyzer is integrated to [&hellip;]<\/p>\n","protected":false},"featured_media":17639,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"pwb-brand":[233],"product_brand":[],"product_cat":[201,202,204],"product_tag":[266],"class_list":{"0":"post-17638","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"pwb-brand-stack-process-cems","7":"product_cat-gases","8":"product_cat-manual-automatic-stack-testing-equipment","9":"product_cat-specialised-products","10":"product_tag-thc","11":"yith_product_brand-gasmet","12":"desktop-align-left","13":"tablet-align-left","14":"mobile-align-left","16":"first","17":"instock","18":"shipping-taxable","19":"product-type-simple"},"acf":[],"brands":[{"id":233,"name":"Stack, Process &amp; CEMS","slug":"stack-process-cems"}],"_links":{"self":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product\/17638","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media\/17639"}],"wp:attachment":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media?parent=17638"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/pwb-brand?post=17638"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_brand?post=17638"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_cat?post=17638"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_tag?post=17638"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}