{"id":20185,"date":"2024-06-18T13:56:26","date_gmt":"2024-06-18T03:56:26","guid":{"rendered":"https:\/\/thomsongroup.com.au\/?post_type=product&#038;p=20185"},"modified":"2024-06-19T14:39:13","modified_gmt":"2024-06-19T04:39:13","slug":"gaseye-extractive","status":"publish","type":"product","link":"https:\/\/thomsongroup.com.au\/product\/gaseye-extractive\/","title":{"rendered":"GasEye Extractive"},"content":{"rendered":"<p>The GasEye Extractive is a versatile gas analyzing tool for industrial process applications. A process gas sample is continuously fed into the analyzer where it is analyzed in real-time utilizing laser absorption spectroscopy.<\/p>\n<p>It can be configured to operate in the near-infrared (NIR), mid-infrared (MIR), and infrared (IR) wavelength range thereby allowing to analyze the majority of gases of interest in the industrial process monitoring.<\/p>\n<p>GasEye Extractive analyzer is assembled in a 19\u201d RACK IP20 or wall-mounted IP66 enclosure.<\/p>\n<h6>Applications<\/h6>\n<ul>\n<li>Safety monitoring<\/li>\n<li>Process Control<\/li>\n<li>Custody transfer.<\/li>\n<\/ul>\n<h6>Industries<\/h6>\n<ul>\n<li>Chemical industry<\/li>\n<li>Petrochemical industry<\/li>\n<li>Food industry.<\/li>\n<\/ul>\n<div class=\"et_pb_row et_pb_row_2\">\n<div class=\"et_pb_column et_pb_column_1_2 et_pb_column_6 et_pb_css_mix_blend_mode_passthrough\">\n<div class=\"et_pb_module et_pb_text et_pb_text_3 et_pb_text_align_justified et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<h6>Features<\/h6>\n<ul>\n<li><strong>Sample temperature:<\/strong> 0 \u2013 200\u00b0C<\/li>\n<li><strong>Real time sensing:<\/strong> response time below 1s<\/li>\n<li><strong>High selectivity: <\/strong>automatic compensation for interference effect from other constituents in the gas sample<\/li>\n<li><strong>High sensitivity:<\/strong> detection limits down to ppb range<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"et_pb_column et_pb_column_1_2 et_pb_column_7 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_text et_pb_text_4 et_pb_text_align_justified et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<ul>\n<li><strong>Maintenance free<\/strong>: equipped with a self-calibrating feature, no field calibration necessary<\/li>\n<li><strong>ATEX<\/strong> version available<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"et_pb_row et_pb_row_3\">\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_column_8 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_text et_pb_text_5 et_pb_text_align_justified et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<h6>Most common application<\/h6>\n<table border=\"0\">\n<tbody>\n<tr>\n<td><strong>Model:<\/strong><\/td>\n<td><strong>Minimum range:<\/strong><\/td>\n<td><strong>Typical Application:<\/strong><\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive H2O<\/td>\n<td>0 \u2013 5 ppmv<\/td>\n<td>Moisture in NG, LNG, H2<\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive H2S<\/td>\n<td>0 \u2013 10 ppmv<\/td>\n<td>H2S in NG, LNG, H2<\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive H2<\/td>\n<td>0 \u2013 10 vol%<\/td>\n<td>Hydrogen applications<\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive CO\/CO2\/CH4<\/td>\n<td>CO: 0 \u2013 1 ppmv<br \/>\nCO2: 0 \u2013 2 ppmv<br \/>\nCH4: 0 \u2013 10 ppmv<\/td>\n<td>Hydrogen purity PSA\/PSA+<\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive HCOOH\/HCHO\/NH3<\/td>\n<td>HCOOH: 0 \u2013 1 ppmv<br \/>\nHCHO: 0 \u2013 1 ppmv<br \/>\nNH3: 0 \u2013 1 ppmv<\/td>\n<td>Hydrogen purity<\/td>\n<\/tr>\n<tr>\n<td>GasEye Extractive H2\/O2<\/td>\n<td>H2: 0 \u2013 10 vol%<br \/>\nO2: 0 \u2013 100 ppmv<\/td>\n<td>Hydrogen applications<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h6>Operating principle<\/h6>\n<p>GasEye Extractive is a laser spectrometer that uses single line molecular absorption spectroscopy. A semiconductor laser emits a beam of infrared light which passes through the process and impinges the detector on the receiver side. When the target gas is present the light intensity changes and this can be used to determine the concentration of the measured specimen. The wavelength of the radiation emitted by the laser is chosen to match the specific absorption line wavelength of the gas. The laser continuously scans this single absorption line with a very high spectral resolution. The measurement is free of cross-interferences since the laser light is absorbed very selectively by only one specific line in the scanned spectral range.<\/p>\n<p><img decoding=\"async\" class=\"\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/AirOptic_wavelength_scanning_process.webp\" alt=\"\"><\/p>\n<div class=\"et_pb_module et_pb_text et_pb_text_7 et_pb_text_align_justified et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<h6>19&#8243; RACK VERSION<\/h6>\n<h6>&nbsp;<\/h6>\n<p><strong>GasEye Extractive 19\u2033 RACK<\/strong> analyzer is assembled in a standard 19-inch rack 4U version.<\/p>\n<p>It exists in several various configurations from single gas to multi gas applications.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-20186\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC.png\" alt=\"\" width=\"1367\" height=\"607\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC.png 1367w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC-300x133.png 300w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC-1024x455.png 1024w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC-768x341.png 768w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC-600x266.png 600w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC-64x28.png 64w\" sizes=\"(max-width: 1367px) 100vw, 1367px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-20187\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back.png\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back.png 1280w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back-300x169.png 300w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back-1024x576.png 1024w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back-768x432.png 768w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back-600x338.png 600w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_back-64x36.png 64w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-20188\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front.png\" alt=\"\" width=\"1280\" height=\"720\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front.png 1280w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front-300x169.png 300w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front-1024x576.png 1024w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front-768x432.png 768w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front-600x338.png 600w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_RAC_front-64x36.png 64w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<table border=\"0\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Specification:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Dimensions:<\/td>\n<td>width x height: 482 mm x 177 mm<br \/>\nlength: 650 mm<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Weight:<\/td>\n<td>35 kg (for the model with multipass cell, vacuum pump, and safety valves)<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Gas connection:<\/td>\n<td>6 mm tubing<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection:<\/td>\n<td>IP20 to EN 60529<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Materials:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Housing:<\/td>\n<td>aluminium<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Internal process cell:<\/td>\n<td>stainless steel 316<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Cell window:<\/td>\n<td>sapphire<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>&nbsp;Climatic conditions<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Ambient temperature:<\/td>\n<td>5\u00baC to 40\u00baC<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Ambient pressure:<\/td>\n<td>800 \u2013 1200 hPa<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Ambient humidity:<\/td>\n<td>RH &lt; 90%, non-condensing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Measurement conditions<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Sample gas pressure:<\/td>\n<td>0.05 \u2013 5 barG<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Sample gas temperature:<\/td>\n<td>ambient<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Sample gas flow:<\/td>\n<td>0.5 \u2013 20 Ndm3\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"3\"><strong>Safety:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\" rowspan=\"2\"><strong>Low Voltage Directive (LVD) 2014\/35\/EU<\/strong><\/td>\n<td>PN-EN 60825-1:2014-11 \u2013 Safety of laser products \u2013 Part 1: Equipment classification and requirements<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>PN-EN 61010-1:2011 \u2013 Safety requirements for electrical equipment for measurement, control and laboratory use \u2013 Part 1: General requirements<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td><strong>EMC Directive 2014\/30\/EU<\/strong><\/td>\n<td>EN 61326-1:2013-6 \u2013 Electrical equipment for measurement, control and laboratory use<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td><strong>RoHS Directive 2<\/strong><strong>011\/65\/EU<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h6>WALL MOUNTED VERSION<\/h6>\n<p>The <strong>GasEye Extractive Wall Mounted <\/strong>type analyzer exists in general purpose and hazardous area configuration (version Ex1). It exists in several various configurations from single-gas to multi-gas applications. The system is IP66 rated with ambient temperature ranges from -30\u00baC to +60\u00baC and can be mounted outside without a need for a container.<\/p>\n<p>GasEye Extractive Ex1 provides Ex p (purge and pressurization) type of explosion protection. Ex p pressurized equipment is the technique of guarding against the ingress of the external atmosphere into an enclosure by maintaining a protective gas therein at a pressure above that of the external atmosphere. The overpressure is maintained either with or without a continuous flow of the protective gas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20189\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom.png\" alt=\"\" width=\"935\" height=\"473\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom.png 935w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom-300x152.png 300w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom-768x389.png 768w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom-600x304.png 600w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_bottom-64x32.png 64w\" sizes=\"(max-width: 935px) 100vw, 935px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20190\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_front.png\" alt=\"\" width=\"673\" height=\"864\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_front.png 673w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_front-234x300.png 234w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_front-600x770.png 600w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_front-64x82.png 64w\" sizes=\"(max-width: 673px) 100vw, 673px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20191\" src=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_side.png\" alt=\"\" width=\"367\" height=\"895\" srcset=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_side.png 367w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_side-123x300.png 123w, https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Extractive_wall_side-64x156.png 64w\" sizes=\"(max-width: 367px) 100vw, 367px\" \/><\/p>\n<table border=\"0\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Specification:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Dimensions:<\/td>\n<td>width x height: 460 mm x 230 mm<br \/>\ndepth: 650 mm<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Weight:<\/td>\n<td>60 kg<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Gas connection:<\/td>\n<td>connector 6 mm Swagelok<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Materials:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Housing:<\/td>\n<td>SS 1.4301 (AISI 304)<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Internal process cell:<\/td>\n<td>SS 1.4404 (AISI 316L)<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Cell window:<\/td>\n<td>sapphire<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Climatic conditions:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Ambient temperature:<\/td>\n<td>-30\u00baC to +60\u00baC<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Ambient pressure:<\/td>\n<td>800 \u2013 1200 hPa<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Ambient humidity:<\/td>\n<td>RH &lt; 90%, non-condensing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"2\"><strong>Measurement conditions:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Precision:<\/td>\n<td>+\/- 1% of the measured value or LOD and response time 30 sec<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Accuracy:<\/td>\n<td>+\/- 2% of the measured value or LOD and response time 30 sec<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Conditioning of the sample:<\/td>\n<td>dry, free from oils and particles<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Calibration:<\/td>\n<td>factory calibration using certified gas<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Zero drift and span drift:<\/td>\n<td>irrelevant<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Sample temperature:<\/td>\n<td>0\u00b0C to 200\u00b0C (depends on application)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\" colspan=\"3\"><strong>Safety:<\/strong><\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\" rowspan=\"2\"><strong>Low Voltage Directive (LVD) 2014\/35\/EU<\/strong><\/td>\n<td>PN-EN 61010 \u2013 1:2011- Safety requirements for electrical equipment for measurement, control and laboratory use<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>PN-EN 60825 \u2013 1:2014-11- Safety of laser products<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td><strong>EMC Directive 2014\/30\/EU<\/strong><\/td>\n<td>EN 61326-1:2013-06 \u2013 Electrical equipment for measurement, control and laboratory use<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td><strong>RoHS Directive 2011\/65\/EU<\/strong><\/td>\n<td>\n<table>\n<tbody>\n<tr id=\"producttabelrow1-1\">\n<td>EN IEC 60079-0:2018 \u2013 Explosive atmospheres \u2013 Part 0: Equipment \u2013 General requirements<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>EN 60079-2:2014 \u2013 Explosive atmospheres \u2013 Part 2: Equipment protection by pressurized enclosure \u201cp\u201d<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>EN 60079-26:2015 \u2013 Explosive atmospheres \u2013 Part 26: Equipment with Equipment Protection Level (EPL) Ga<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>EN 60079-28:2015 \u2013 Explosive atmospheres \u2013 Part 28: Protection of equipment and transmission systems using optical radiation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\" rowspan=\"8\"><strong>ATEX Directive 2014\/34\/EU<\/strong><\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td>Explosion protection (standard version):<\/p>\n<ul>\n<li>ATEX II 3G [Ex op is IIC T6 Gc]<\/li>\n<li>ATEX II 3D [Ex op is IIIC T85\u00b0C Dc]<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td>Explosion protection \u2013 ATEX Zone 1\/21 (optional version):<\/p>\n<p>GasEye Extractive Ex1:<\/p>\n<ul>\n<li><img decoding=\"async\" src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" width=\"21\" data-src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" data-pagespeed-url-hash=\"31059146\"> II 1\/2G Ex op is pxb IIC T* Ga\/Gb<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" width=\"21\" data-src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" data-pagespeed-url-hash=\"31059146\"> II 1\/2D Ex op is pxb IIIC T** Da\/Db<\/li>\n<\/ul>\n<p>GasEye Extractive Ex1 ET:<\/p>\n<ul>\n<li><img decoding=\"async\" src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" width=\"21\" data-src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" data-pagespeed-url-hash=\"31059146\"> II 1\/2G Ex db eb h ia ib op is pxb q IIC T* Ga\/Gb<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" width=\"21\" data-src=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/ATEX_logo.gif\" data-pagespeed-url-hash=\"31059146\"> II 1\/2D Ex h ia ib op is tb pxb q IIIC T** Da\/Db<\/li>\n<\/ul>\n<p>*\/** temperature class depends on the medium temperature according to:<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td><strong>ID<\/strong><\/td>\n<td><strong>Medium temperature:<\/strong><\/td>\n<td><strong>Ambient conditions:<\/strong><\/td>\n<td><strong>Temperature class:<\/strong><\/td>\n<td><strong>Maximum surface temperature:<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>&lt; 50\u00b0C<\/td>\n<td>-30\u00b0C to 50\u00b0C<\/td>\n<td>T6<\/td>\n<td>85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>&lt; 100\u00b0C<\/td>\n<td>-30\u00b0C to 60\u00b0C<\/td>\n<td>T5<\/td>\n<td>100\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>&lt; 135\u00b0C<\/td>\n<td>-30\u00b0C to 60\u00b0C<\/td>\n<td>T4<\/td>\n<td>135\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>&lt; 200\u00b0C<\/td>\n<td>-30\u00b0C to 60\u00b0C<\/td>\n<td>T3<\/td>\n<td>200\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a href=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/Extractive_KDB_20ATEX0056X_1st_EN.pdf\" download=\"\">Certificate No. KDB 20ATEX0056X EN<\/a><br \/>\n<a href=\"https:\/\/www.airoptic.pl\/wp-content\/uploads\/2022\/10\/Extractive_KDB_20ATEX0056X_1st_PL.pdf\" download=\"\">Certificate No. KDB 20ATEX0056X PL<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<a class=\"fasc-button fasc-size-xlarge fasc-type-glossy fasc-rounded-medium\" style=\"background-color: #1a4f7b; color: #ffffff;\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Airoptic_GasEye-Extractive.pdf\">Download Specifications<\/a>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The GasEye Extractive is a versatile gas analyzing tool for industrial process applications. A process gas sample is continuously fed into the analyzer where it is analyzed in real-time utilizing laser absorption spectroscopy. It can be configured to operate in the near-infrared (NIR), mid-infrared (MIR), and infrared (IR) wavelength range thereby allowing to analyze the [&hellip;]<\/p>\n","protected":false},"featured_media":20192,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"pwb-brand":[233],"product_brand":[],"product_cat":[201,239],"product_tag":[280,299,291,277,335,336,260,278,343,290],"class_list":{"0":"post-20185","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"pwb-brand-stack-process-cems","7":"product_cat-gases","8":"product_cat-process","9":"product_tag-co","10":"product_tag-co2","11":"product_tag-h2o","12":"product_tag-h2s","13":"product_tag-hcho","14":"product_tag-hcooh","15":"product_tag-methane-ch4","16":"product_tag-nh3","17":"product_tag-no","18":"product_tag-o2","19":"yith_product_brand-airoptic","20":"desktop-align-left","21":"tablet-align-left","22":"mobile-align-left","24":"first","25":"instock","26":"shipping-taxable","27":"product-type-simple"},"acf":[],"brands":[{"id":233,"name":"Stack, Process &amp; CEMS","slug":"stack-process-cems"}],"_links":{"self":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product\/20185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media\/20192"}],"wp:attachment":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media?parent=20185"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/pwb-brand?post=20185"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_brand?post=20185"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_cat?post=20185"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_tag?post=20185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}