{"id":20201,"date":"2024-06-18T15:42:54","date_gmt":"2024-06-18T05:42:54","guid":{"rendered":"https:\/\/thomsongroup.com.au\/?post_type=product&#038;p=20201"},"modified":"2025-05-22T09:25:42","modified_gmt":"2025-05-21T23:25:42","slug":"gaseye-probe-h2o","status":"publish","type":"product","link":"https:\/\/thomsongroup.com.au\/product\/gaseye-probe-h2o\/","title":{"rendered":"GasEye Probe H2O"},"content":{"rendered":"<p>GasEye H2O is a high performance in-situ water vapor analyzer. Suitable for safety applications and process control. 24\/7 continuous operation. No sample preparation. No zero drift. No field calibration. Low cost of ownership.<\/p>\n<h6>Features<\/h6>\n<p>\u2022 H2O ranges: 0 \u2013 1000 ppmv \/ 0 \u2013 100%vol<br \/>\n\u2022 Process temperatures 0-500\u00b0C<br \/>\n\u2022 Process pressures 0.7-2.0 barA<br \/>\n\u2022 Real time sensing \u2013 response time below 0.1 second<br \/>\n\u2022 High sensitivity \u2013 detection limit below 10 ppm per meter<br \/>\n\u2022 High selectivity \u2013 automatic compensation for interference effect from other constituents in the gas sample<br \/>\n\u2022 In-situ monitoring \u2013 direct in the process, no sample preparation<br \/>\n\u2022 Maintenance free \u2013 equipped with a self-calibrating feature, no field calibration necessary<br \/>\n\u2022 Robustness \u2013 IP66 enclosure, suitable for outdoor and indoor installations and harsh environments<br \/>\n\u2022 Insensitive to dust and smoke in the measured process \u2013 up to 50 g\/m3.<\/p>\n<h6>Example Applications<\/h6>\n<p>\u2022 Gas quality measurement<br \/>\n\u2022 Safety monitoring<br \/>\n\u2022 Process control<\/p>\n<h6>Example Industries<\/h6>\n<p>\u2022 Petrochemical industry<br \/>\n\u2022 Power industry<br \/>\n\u2022 Steel industry<br \/>\n\u2022 Chemical industry<\/p>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Analytical performance:<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">H2O measurement range:<\/td>\n<td>0-30 vol%<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">LoD:<\/td>\n<td>0.1 vol% *m @STP and 3 sec response time<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Precision:<\/td>\n<td>LOD or 1% of the measured value, whichever is larger @STP and 3 sec response time<\/td>\n<\/tr>\n<tr>\n<td>Accuracy:<\/td>\n<td>LOD or 2% of the measured value, whichever is larger @STP and 3 sec response time<\/td>\n<\/tr>\n<tr>\n<td>Process dust load:<\/td>\n<td>up to 50 g\/Nm3 depending on the process<\/td>\n<\/tr>\n<tr>\n<td>Calibration:<\/td>\n<td>Certified span gas<\/td>\n<\/tr>\n<tr>\n<td>Zero drift and span drift:<\/td>\n<td>negligible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Electric characteristics:<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Power input:<\/td>\n<td>24 VDC nominal (19 &#8211; 30 VDC)<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Power consumption:<\/td>\n<td>&lt; 20 VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Dynamic performance:<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Warmup time:<\/td>\n<td>approx. 5 minutes<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Minimum response time (T90):<\/td>\n<td>200 milliseconds<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Electric inputs and outputs<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Inputs:<\/td>\n<td>4 x analog input, (4-20 mA, process temperature and pressure, 2 x AUX) &#8211; easy user selection via DIP switch between active\/passive mode<br \/>\n1 x RTD<br \/>\n8 x Digital input<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Outputs:<\/td>\n<td>4 x analog output, (4-20 mA, H2O concentration, process transmission, 2 x AUX, ) active or passive &#8211; easy user selection via DIP switch between active\/passive mode, selectable signal ranges according to EN 15267-3 or NAMUR NE43<br \/>\n8 x Digital output (MOSFET-based), optionally 4 x dry contact DO<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-3\">\n<td id=\"producttabelname1\">Optional:<\/td>\n<td>PROFINET, Modbus (TCP\/IP), Modbus RTU, Profibus DPO<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-3\">\n<td id=\"producttabelname1\">Local User Interface:<\/td>\n<td>1. Local User Local User Interface: Interface (LUI) \u2013 LCD backlight display located on the transmitter housing lid.<br \/>\n2. Ethernet<br \/>\n\u2022 WebServer application \u2013 system configuration and data acquisition via webbrowser<br \/>\n\u2022 Windows based program \u2013 GasEye logger for real time data acquisition<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-3\">\n<td id=\"producttabelname1\">Remote Access:<\/td>\n<td>Ethernet port for remote service and diagnostics<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Mechanical specification<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Degree of protection:<\/td>\n<td>In accordance with IP66<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Process flange:<\/td>\n<td>DN50PN16<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Process windows:<\/td>\n<td>F.Silica window, Helium leak tested and certified in accordance to EN1779:2002 norm.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Instrument dimensions:<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Analyzer:<\/td>\n<td>W x H x L: 330 mm x 230 mm x 323 mm<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Analyzer with probe:<\/td>\n<td>W x H x L: 330 mm x 230 mm x 1600 mm<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-3\">\n<td id=\"producttabelname1\">Active optical path length:<\/td>\n<td>L: 2x 578 mm<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-4\">\n<td id=\"producttabelname1\">Weight:<\/td>\n<td>Analyzer (including probe): 18 kg Probe: 6 kg<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-5\">\n<td id=\"producttabelname1\">Materials:<\/td>\n<td>Housing: aluminium<br \/>\nCoating: RAL5010<br \/>\nProcess interface: Stainless steel 316<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><a class=\"fasc-button fasc-size-xlarge fasc-type-glossy fasc-rounded-medium\" style=\"background-color: #1a4f7b; color: #ffffff;\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/thomsongroup.com.au\/wp-content\/uploads\/2024\/06\/Airoptic_GasEYE_Probe_H2O_.pdf\">Download Specifications<\/a><\/p>\n<table border=\"1\">\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Climatic conditions<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Ambient temperature:<\/td>\n<td>800 &#8211; 1200 hPa<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Ambient humidity:<\/td>\n<td>RH &lt; 99%, non-condensing<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Measurement conditions<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Sample gas pressure:<\/td>\n<td>0.7 &#8211; 2 barA<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Sample gas temperature:<\/td>\n<td>0\u00baC to 500\u00baC<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Sensor and Process Purging (Nitrogen)<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Purging gas flow rate:<\/td>\n<td>\u2013 50 l\/min (process dependent)<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr id=\"producttabelrow0\">\n<td id=\"producttabelname2\"><strong>Safety<\/strong><\/td>\n<td id=\"producttabelname2\">&nbsp;<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-1\">\n<td id=\"producttabelname1\">Low Voltage Directive (LVD) 2014\/35\/EU<\/td>\n<td>PN-EN 61010-1:2011<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">Laser radiation:<\/td>\n<td>Laser Class I product acc. to PN-EN 60825-1:2014-11<\/td>\n<\/tr>\n<tr id=\"producttabelrow1-2\">\n<td id=\"producttabelname1\">EMC Directive 2014\/30\/EU:<\/td>\n<td>EN IEC 61326-1:2021<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>GasEye H2O is a high performance in-situ water vapor analyzer. Suitable for safety applications and process control. 24\/7 continuous operation. No sample preparation. No zero drift. No field calibration. Low cost of ownership. Features \u2022 H2O ranges: 0 \u2013 1000 ppmv \/ 0 \u2013 100%vol \u2022 Process temperatures 0-500\u00b0C \u2022 Process pressures 0.7-2.0 barA \u2022 [&hellip;]<\/p>\n","protected":false},"featured_media":20761,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"pwb-brand":[233],"product_brand":[],"product_cat":[201,239],"product_tag":[291],"class_list":{"0":"post-20201","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"pwb-brand-stack-process-cems","7":"product_cat-gases","8":"product_cat-process","9":"product_tag-h2o","10":"yith_product_brand-airoptic","11":"desktop-align-left","12":"tablet-align-left","13":"mobile-align-left","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"acf":[],"brands":[{"id":233,"name":"Stack, Process &amp; CEMS","slug":"stack-process-cems"}],"_links":{"self":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product\/20201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media\/20761"}],"wp:attachment":[{"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/media?parent=20201"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/pwb-brand?post=20201"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_brand?post=20201"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_cat?post=20201"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/thomsongroup.com.au\/wp-json\/wp\/v2\/product_tag?post=20201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}