Spark CO2

Accurate, Consistent & Drift-Free CO2 Measurements

TIGER OPTICS™ Spark™ CO2 analyzer is ideal for trace monitoring of critical impurities in nitrogen and other pressurized gases. Based on powerful Cavity Ring-Down Spectroscopy (CRDS), with a proprietary laser-locked cell, the Spark is free of drift, guaranteeing consistent and reliable trace CO2 detection in nitrogen and other inert gases. Highly specific to the target molecule, CRDS also prevents cross-interferences from distorting your measurement.  Plus, there is no need to perform costly and time-consuming zero and span calibrations, saving both time and money with continuous, on-line service. 

Compact, affordable and powerful, the new Spark CH2 brings you:

  • Trace CO2 detection limit down to 250 ppb
  • Wide dynamic measurement range
  • Drift-free performance
  • Immunity to vibration
  • No spectral interferences
  • Compact standalone footprint or rack-mountable
  • Low Cost of Ownership
  • Simple operation
  • Serani™ interface software for remote analyzer control & data analysis.

Applications

  • Air Separation Units & Nitrogen Plants
  • Gaseous CRMs & Calibration Gas Mixtures
  • High-Purity Gases & Systems
  • Hydrogen Fuel Cells
  • Research & Development.

Process Insights also offers a new CRDS analyzer performance upgrade. Implementing dynamic data processing, the Speed+™ Analyzer Performance Upgrade Software adjusts your analyzer’s response automatically and in real-time to deliver the best performance.  Benefits of Speed+ for your operations include real-time process control to ensure quality, as well as faster throughput and increased capacity to improve efficiency and profitability.

Serani™ Max Analyzer Interface Software allows you to have remote access from your computer or laptop for our latest CRDS generation analyzers, such as the Halo KA Max and T-I Max. The Windows-based software package communicates with the analyzer through Ethernet and allows full control of the system conveniently from your desk.
 

Download Data Sheet

Brand

Laboratory & Scientific

Stack, Process & CEMS

Detection Capability

 

Detection and Matrix Range LDL (3σ) Precision (1σ) @ zero
CO2 in N2 0 – 1500 ppm 250 ppb 80 ppb
CO2 in O2 0 – 1200 ppm 220 ppb 75 ppb
CO2 in Clean Dry Air (CDA) 0 – 1500 ppm 250 ppb 80 ppb
CO2 in Ar 0 – 1200 ppm 220 ppb 75 ppb
CO2 in He 0 – 1200 ppm 220 ppb 75 ppb
CO2 in H2 0 – 2000 ppm 400 ppb 140 ppb

Specifications

Performance
Operating range See Detection Capability table
Detection Limit (3σ/24h) See Detection Capability table
Precision (1σ, greater of) ± 0.75% or 1/3 of LDL
Accuracy (greater of) ± 4% or LDL
Speed of response < 1 minute to 90%
Environmental conditions 10°C to 40°C, 30% to 80% RH (non-condensing)
Storage temperature -10°C to 50°C
Gas Handling System and Conditions
Wetted materials 316L stainless steel, 10 Ra surface finish
Gas connections 1/4″ male VCR inlet and outlet
Inlet pressure 10 – 125 psig (1.7 – 9.6 bar)
Flow rate ∼0.7 slpm (in N2), gas-dependent
Sample gases Most inert and passive matrices
Gas temperature Up to 60°C
Dimensions, H x W x D
Standard sensor 8.73″ x 8.57″ x 23.6″ (222 mm x 218 mm x 599 mm)
Sensor rack (fits up to two sensors) 8.73″ x 19.0″ x 23.6″ (222 mm x 483 mm x 599 mm)
Weight
Standard sensor 32 lbs (14.5 kg)
Electrical
Alarm indicators 2 user programmable, 1 system fault, Form C relays
Power requirements 90 – 240 VAC, 50/60 Hz
Power consumption 40 Watts max.
Signal output Isolated 4–20 mA per sensor
User interfaces 5.7″ LCD touch screen, 10/100 Base-T Ethernet, RS-232RS-485, Modbus TCP (optional)
Data Storage Internal or external flash drive
Patents
U.S. Patent #7,277,177

Request information or pricing

If you need a quote, specifications or technical info, or anything else – please submit the form below and one of our team of experts will happily get back to you within 24 business hours. 

  • This field is for validation purposes and should be left unchanged.